Selecting A Timecode Source - Yamaha D24 Owner's Manual

Yamaha digital multitrack recorder owner's manual
Hide thumbs Also See for D24:
Table of Contents

Advertisement

Selecting a Timecode Source

The timecode source is selected using the TC Select function. Settings other than MAS-
TER are used when the D24 is synchronized to external timecode. In addition to select-
ing the source, you must also set the frame rate. See "Setting the Timecode Frame Rate"
on page 136 for more information. The TC Select setting is not stored with each project.
See "About Projects" on page 30 for more information.
Press the [SETUP] button.
1
The SETUP indicator lights up.
Use the JOG/DATA dial to select "TC SELECT," and then press the [ENTER]
2
button.
The currently selected timecode source appears on the display.
Use the JOG/DATA dial to select a timecode source.
3
The following timecode sources can be selected:
Source
MASTER
TIME CODE IN
MIDI IN
REMOTE IN
SERIAL IN
TC IN+VIDEO
Press the [ENTER] button to activate your selection, or the [CANCEL] button
4
to cancel the TC Select function.
When the timecode source is set to MASTER, "MASTER"
appears in the TC window on the display, and when it's set to
TIME CODE IN, MIDI IN, REMOTE IN, or SERIAL IN,
"SLAVE" appears, as shown here.
Press the [SETUP] button again to leave setup.
5
The SETUP indicator goes out.
When the timecode source is set to REMOTE IN, the wordclock source is also set to
REMOTE IN (the EXT indicator in the WC window lights up) and the D24 is automat-
ically configured as a wordclock slave. When the timecode source is set to a different
source, the wordclock source reverts to its previous setting.
Internal SMPTE/EBU timecode (default setting).
External SMPTE/EBU timecode via the TIME CODE IN. Used when syn-
chronizing the D24 to external timecode.
External MTC timecode via the MIDI IN port. Used when synchronizing
the D24 to external timecode.
External SMPTE/EBU timecode via the REMOTE IN/SYNC IN. Used when
synchronizing slave D24s to the timecode from the master D24 in a mul-
tiple unit system.
External SMPTE/EBU timecode via the TIME CODE IN and command
information via the SERIAL I/O port. Used when synchronizing the D24
to external timecode and controlling via command information received
at the SERIAL I/O port.
External SMPTE/EBU timecode via the TIME CODE IN and video sync via
the VIDEO INPUT. Used when synchronizing the D24 to external time-
code and video sync.

Selecting a Timecode Source

Description
TC
TC
D24—Owner's Manual
135
MASTER
SLAVE