E1 Debugger Configuration

Table 6-7 below details the function of the option links associated with E1 Debugger configuration.
MCU
Signal name
CS2n_TXD1
22
RXD1
20
CS0n_TXD8_PC7
45
Items shown in
bold
are the Fit / Do Not Fit (DNF) default configuration that the RSK is supplied with.
Rev.
R20UT3027EG0100
1.00
Aug 24, 2015
MCU Peripheral Selection
Signal
Fit
CS2n
R97
P26
TXD1
R237
RXD1
P30
-
CS0n
R101
TXD8
R212
PC7
PC7
R248
Table 6-7: E1 Debugger Option Links
Interface
DNF
/Function
R237
JA3.28
E1.5
R97
U11.3
JA6.8
E1.11
-
U9.3
JA6.7
R212, R248
JA3.27
R101
PMOD1.2
E1.10
R101
SW4.2
6.
Configuration
Destination Selection
Fit
DNF
-
-
R238
-
R234
R156, R154,
-
-
R249
-
R157, R153,
R251
R155
-
-
-
-
-
R243
-
-
-
Page 30 of 53
R179
R176