source A. If the range is selected relative to the main frequency source, the range of the
auxiliary frequency source Frequency A changes
Frequency source
combination mode
P0-07
Set range
Use this parameter to select the frequency reference channel. The frequency reference is
achieved by a combination of the main frequency source A and the auxiliary frequency
source B (Pic 6-2)
When the frequency source is selected as the main and auxiliary operation, the offset
frequency can be set by P0-21, and the offset frequency is superimposed on the main and
auxiliary operation results to flexibly cope with various requirements.
Preset the set
P0-08
frequency
selection
Bit
0: Main frequency source A
1: Main and auxiliary operation result (calculation relationship is
determined by ten bits)
2: Main frequency source A and auxiliary frequency source B
switching
3: Main frequency source A and master and slave operation result
switching
4: auxiliary frequency source B and master and slave operation
result switching
Frequency source main and auxiliary operation
Bit
relationship
0:main + auxiliary
2:max
Factory default
Factory default
Frequency source selection
1:main-auxiliary
3:min.
- 62 -
0
50.00Hz