AC Drive's
3000H
2. Control Parameters
The control parameters include control command, communication
setting values, AO1 control, AO2 control, high-speed pulse (FMP)
output control and parameter initialization.
● Control commands
When P0-02 (command source selection) is set to 2 (serial
comms.), you can
Implement control such as start/stop of the AC drive by using
communication address.
The control commands are defined in the following table.
Communication
Address of AC
Drive's Running
Status
2000H
1: Forward run
2: Reverse run
3: Stop
Status Definition
1: Forward run
2: Reverse run
3: Forward jog
4: Reverse jog
5: Coast to stop
6: Decelerate to stop
7: Fault reset