Motorola GTR 8000 Manual page 217

Astro 25 integrated voice and data base radio
Table of Contents

Advertisement

3
Configure the Speed/Duplex setting in the PCs Ethernet interface to 10 Mb Half Duplex.
Connect to the base radio in CSS through an Ethernet connection. See
4
Port Link, page
5
Select Service → Test and Measurement Screen from the menu.
Step result: The Test and Measurement Screen dialog box appears.
6
Disable the channel that is using the base radio you will test.
The test procedures require the base radios Rx and Tx cables to be connected to the HPD Service
Monitor. Any calls present on the channel associated with the base radio will be dropped from that
channel. It is recommended that you disable the channel before performing the test procedures, so
that the system does not attribute the loss of channel to a failure.
If the base radio is not already in service mode, click Change to Service Mode.
Step result: A confirmation dialog box appears.
7
Click OK.
Step result: The base radio goes through a reset sequence to change modes. This takes a few seconds.
8
After the station resets, re-open the Test and Measurement Screen, as described in
If measuring the base radios transmit signal, connect the Tx connector at the rear of the base radio to the T/R
9
(Transmit/Receive) port on the front of the service monitor. (Both are N-type RF connectors.)
10 If measuring the base radios receive signal, connect the Rx-A and Rx-B ports at the rear of the base radio to the
GEN port on the front of the service monitor, using a splitter.
11 Press the green power button on the front of the service monitor.
12 If the Test Screen is not displayed (see
13 Locate the specifications for the GTR 8000 Base Radio configuration you will be testing. See
Base Radio/GPW 8000 Receiver Specifications, page
14 If no further testing is needed, click Change to Normal Mode to return the base radio to normal operation.
6871022P86-A - November 2012
4-11.
Figure
5.11.1 Setting Up the HPD Service Monitor for Testing the Base Radio
4.4.4 Connecting Through an Ethernet
5-24), press the Test button on the front of the service monitor.
1-12.
step
5.
1.9 GTR 8000
5-47