Mitsubishi Electric AnyWire NZ2AW1C2AL User Manual page 81

Cc-link-anywireaslink bridge module
Table of Contents

Advertisement

■ASLINKAMP
Product name
Model
Photoelectric fiber
B289SB-01AP-CAM20
type (transmission
B289SB-01AP-CAS
type)
B289SB-01AF-CAM20
B289SB-01AF-CAS
Device parameter
Description of device parameters
Device parameter 1
Threshold value
Specify a threshold value which determines on/off of the
sensor.
Default value: 50
Setting range: 0 to 100
Device parameter 2
Hysteresis value
Specify a hysteresis value for the threshold value.
Default value: 5
Setting range: 0 to 100
Device parameter 3
Alarm determination upper limit value
Specify an alarm determination upper limit value.
Default value: 80
Setting range: 0 to 100
Device parameter 4
Alarm determination lower limit value
Specify an alarm determination lower limit value.
Default value: 20
Setting range: 0 to 100
Device parameter 5
Alarm determination monitoring time
Specify the monitoring time for the alarm determination
value.
Default value: 50 (Unit: 100ms)
Setting range: 3 to 255
Device parameter 6
Light ON / Dark ON setting
Specify the light ON or dark ON setting for the sensor on/
off.
Default value: 0
Setting value: 0 (Dark ON), 1 (Light ON)
Device parameter 7
Operation mode setting
Specify the use of the alarm diagnostics function.
Default value: 0
Setting value: 0 (Diagnostics function not used), 1
(Diagnostics function used)
Device parameter 8
Sensor type setting
Specify a value according to the sensor of the
manufacturer used.
Default value: 0
For setting values, refer to the manual for the slave module
used.
Device parameter 9
Device parameter 10
Device parameter 11
Device parameter 12
Device parameter 13
Read/Write
Read/Write