Maintenance and cleaning
•
Switch the system off.
•
Remove the electrical cable D from the spray gun B.
•
Disconnect the hose for powder feed G, atomizing air F and Tribo air E from the spray gun
B.
•
Unscrew the kinking protection H from the gun.
•
Undo the socket head cap screws K and open the upper part of the cross attaching piece
J.
•
Pull the spray gun out of the cross attaching piece.
•
Replace the spray gun with a new gun and fit this is in the reverse order of removal.
05 / 2009
B
P_00745
0351701
D
K
J
H
- PEA-T3XL
E
F
G
17