9 Normal Operation

Switching On
The device is mounted and installed.
To switch on the device, perform the following steps:
1.
Press the on/off button for 2 s.
Red and blue LEDs illuminate.
Red LED goes out.
Blue LED illuminates and indicates the start process.
Blue LED lights up continuously, AC voltage is activated.
The device is switched on.
Switching Off
To switch off the device, perform the following steps:
1.
Press the on/off button for 0.5 s.
Blue LED goes out.
Device switches off.
The device is switched off.

10 Functions

Standby Mode
If the AC voltage is not required continuously, a standby mode can be
activated. In standby mode, the internal consumption is less than 2 W. In
standby mode, the device generates a short pulse every 2 seconds.
If the actual consumption is more than 10 W, the device
switches on.
If the consumer is switched off, the device switches to standby
mode after 1 minute.
The standby mode cannot be activated or deactivated via an
external remote switch.
The standby mode is not suitable for lithium batteries.
Page 12 of 22