Mounting; Installation - LEAB Clayton Power G3 Combi 1012-50 User Manual

Lightweight and compact sine wave inverter and battery charger
Table of Contents

Advertisement

User Manual

7 Mounting

To mount the device, perform the following steps:
NOTICE
Choose a cool, dry and well-ventilated mounting site. The device must
be protected from dust and moisture.
Do not mount the device directly next to or above batteries.
Mount the device on a flat surface.
Optimum cooling is achieved with vertical mounting.
1.
Fasten the device with screws to the 4 lateral holes (5 mm Ø).
The device is mounted.

8 Installation

Determining the Cable Cross-section of the Input Lead (DC)
The following table shows the required cable cross-sections in relation to
the respective cable length. Select the cross-sections so that the voltage
drop to the G3 Combi is no more than 250 mV.
To avoid voltage dips, select a higher cable cross-section for
consumers with high starting currents (e.g. motors, compressors).
Cable
Cross-
section
2
mm
1012-
50
15
-
25
1.5 m
35
2 m
50
3 m
70
-
Device model
1312-
1512-
2012-
80
80
100
-
-
-
-
1.5 m
1.5 m
2 m
2 m
3 m
2.5 m
Page 10 of 22
1024-
1524-
30
40
-
1.5 m
-
2.5 m
1.5 m
-
3 m
2.5 m
1.5 m
-
2 m
-
Mounting
2324-
50
-
-
-
1.5 m
3 m
2 m
-
3 m