Activating the Standby Mode
To activate the standby mode, perform the following steps:
The device is switched off.
1.
Press the on/off button until the blue and red LEDs illuminate.
The standby mode is activated.
Deactivating the Standby Mode
To deactivate the standby mode, perform the following steps:
The device is switched off.
1.
Press the on/off button until the blue and red LEDs flash.
The standby mode is deactivated.
Battery Charging
The battery is charged automatically as soon as a supply voltage
(185 V – 265 V) is applied to the AC input.
The battery is also charged when the device is switched off.
The charging takes place with reduced charging current when
the supply voltage (AC) is between 110 V and 185 V.
Mains Priority Circuit
The mains priority circuit is activated automatically when a supply voltage
(AC) is applied to the AC input.
If a supply voltage is applied to the AC input, the consumers are supplied
with power by the 230-V mains and batteries are charged by the charger.
Page 13 of 22