Appendix 3-1 Compliance To Ec Directives; Appendix 3-1-1 European Ec Directives; Appendix 3-1-2 Cautions For Ec Directive Compliance - Mitsubishi Electric MELDAS MDS-R Series Technical Specification And Instruction Manual

Hide thumbs Also See for MELDAS MDS-R Series:
Table of Contents

Advertisement

Appendix 3-1 Compliance to EC Directives

Appendix 3-1-1 European EC Directives

In the EU Community, the attachment of a CE mark (CE marking) is mandatory to indicate that the basic
safety conditions of the Machine Directives (issued Jan. 1995), EMC Directives (issued Jan. 1996) and
the Low-voltage Directives (issued Jan. 1997) are satisfied. The machines and devices in which the
servo and spindle drive are assembled are the targets for CE marking.
(1) Compliance to EMC Directives
The servo and spindle drive are components designed to be used in combination with a machine or
device. These are not directly targeted by the Directives, but a CE mark must be attached to
machines and devices in which these components are assembled. The next section "EMC
Installation Guidelines", which explains the unit installation and control panel manufacturing
method, etc., has been prepared to make compliance to the EMC Directives easier.
(2) Compliance to Low-voltage Directives
The MDS-R Series units are targeted for the Low-voltage Directives. An excerpt of the precautions
given in this specification is given below. Please read this section thoroughly before starting use.
A Self-Declaration Document has been prepared for the EMC Directives and Low-voltage
Directives. Contact Mitsubishi or your dealer when required.

Appendix 3-1-2 Cautions for EC Directive compliance

Use the Low-voltage Directive compatible parts for the servo/spindle drive and servo/spindle motor. In
addition to the items described in this instruction manual, observe the items described below.
(1) Configuration
Isolating
transformer
(2) Environment
Use the units under an Overvoltage Category II and Pollution Class of 2 or less environment as
stipulated in IEC60664.
These units do not provide protection against electric shock and fire sufficient for the requirements
of the Low-voltage Directive and relevant European standards by themselves, so provide additional
protection (refer to 5.2.4 and 7.1.6.1 of EN50178)
Drive unit
During
operation
Ambient
0°C to 55°C
temperature
90%RH or
Humidity
less
1000m or
Altitude
less
Appendix 3. Compliance with European EC Directives
Circuit breaker
AC reactor
CB
Use a type B (AC/DC detectable type) breaker
During
Storage
transportation
-15°C to 70°C
-15°C to 70°C
90%RH or
90%RH or less
less
1000m or
13000m or
less
less
Drive unit
Electromagnetic
contactor
MC
Motor
During
operation
Ambient
0°C to 40°C
temperature
80%RH or
Humidity
less
1000m or
Altitude
less
A3 - 2
M
During
Storage
transportation
-15°C to 70°C
-15°C to 70°C
90%RH or
90%RH or
less
less
1000m or
13000m or
less
less

Hide quick links:

Advertisement

Table of Contents
loading