(3) Obtaining the tolerable number of positioning times
The tolerable cycle operation frequency per minute DP is calculated respectively for the standard
built-in regenerative resistor and option regenerative resistor.
Refer to expression (2-10).
• MR-RB30 (300W)
P
R
DP
= 48
= 48×
1
E
R
• MR-RB50 (500W)
P
R
DP
= 48
= 48×
2
E
R
Because the number of times described above is the number of cycle operations for 1 vertical axis
reciprocation, the number of positioning times is 2-fold. Thus, it is apparent that the MR-RB30
(300W) option resistor is required to satisfy the specified positioning frequency of 12 times/min.
With the vertical axis, the regenerative load tends to increase compared to the
POINT
horizontal axis, so provide an allowance when making a selection.
Appendix 2. Selection
300
= 9.79 (times)
1470.6
500
= 16.3 (times)
1470.6
A2 - 12
Number of positioning times = 19.6 (times)
Number of positioning times = 32.6 (times)