Generation f alarms and information messages

Advertisement

Alarm No.
Alarm text
Function
71:2
1052
HC COMPRESSOR MOTOR CONTROL START-UP FAILURE
The compressor motor does not rotate during start up.
71:3
1053
HC COMPRESSOR MOTOR CONTROL OVER OR UNDER
VOLTAGE
Low or high power supply to compressor motor control.
71:4
1054
HC COMPRESSOR OUTSIDE WORKING RANGE
HC compressor works outside its ordinary working
range.
71:9
1059
HC EXPANSION VALVE CONTROL CIRCUIT 1 COMMU-
NICATION ERROR
The air handling unit's control unit cannot establish
correct communication with the HC expansion valve
control circuit 1.
72:1
1066
HC HIGH PRESSURE MONITOR CIRCUIT 1 TRIPPED
The high pressure monitor alarm HC circuit 1, has
tripped.
72:2
1067
HC HIGH PRESSURE CIRCUIT 1 ABOVE ALARM LIMIT
The high pressure alarm HC circuit 1, has tripped.
72:3
1068
HC THERMOSTATIC CONTACT CIRCUIT 1 TRIPPED
The thermostatic contacts alarm HC circuit 1, has
tripped.
72:4
1069
HC HOT GAS TEMPERATURE CIRCUIT 1 ABOVE ALARM
LIMIT
The hot gas temperature alarm HC circuit 1, has tripped.
72:5
1070
HC HOT GAS TEMPERATURE CIRCUIT 1 DEFECTIVE
Hot gas temperature sensor is defective or is not con-
nected.
72:6
1071
HC HIGH PRESSURE SENSOR CIRCUIT 1 DEFECTIVE
High pressure sensor HC circuit 1, is defective or is not
connected.
72:7
1072
HC LOW PRESSURE SENSOR CIRCUIT 1 DEFECTIVE
Low pressure sensor HC circuit 1, is defective or is not
connected.
72:8
1073
HC SUCTION GAS TEMPERATURE CIRCUIT 1 DEFECTIVE
Suction gas line temperature sensor HC circuit 1, is
defective or is not connected.
72:9
1074
HC PRESSURE DIFFERENCE CIRCUIT 1 BELOW ALARM
LIMIT
The pressure difference HC circuit 1, has tripped.
72:10
1075
HC SERVICE OF CIRCUIT 1 AND COMPRESSOR
Service of circuit 1 and compressor required.
72:11
1076
HC OVERHEATING TEMPERATURE CIRCUIT 1 BELOW
ALARM LIMIT
HC overheating temperature circuit 1 falls below the set
alarm limit.
72:12
1077
HC PRESSURE EQUALISATION OF LOW PRESSURE CIR-
CUIT 1
HC pressure equalisation low pressure circuit 1, has
tripped.
72:13
1078
HC PRESSURE EQUALISATION OF HIGH PRESSURE
CIRCUIT 1
HC pressure equalisation high pressure circuit 1, has
tripped.
72:14
1079
HC LOW PRESSURE CIRCUIT 1 BELOW ALARM LIMIT
HC low pressure circuit 1 falls below the set alarm limit.
32
www.swegon.com
GB.GOLDSKFLARM.190920
Priority
Stop
0 = Blocked 0 = In oper. s = second
A = A alarm
1 = Stop
m = minute 1 = automatic
B = B alarm
h=hour
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
B
0
A
0
A
0
A
0
A
0
We reserve the right to alter specifications without notice.
Delay
Resetting
0 = manual
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1
10 s
1