Checking The Operating Fluid - EMG ELDRO Ed 12/4 Assembly Manual

Electro-hydraulic lifting thrusters, standard range and special designs (three-phase voltage version)
Table of Contents

Advertisement

9
Maintenance
9.1
Maintenance tasks
9.1.2

Checking the operating fluid

72 / 83
WARNING
Hot operating fluid
Risk of burns due to hot oil plumes when opening the filling screw
when at operational heat.
– The operating fluid may only be checked, topped up or
drained when switched off and cool.
®
– The ELDRO
temperature of 40 °C.
NOTE
If not filled sufficiently, the thruster does not develop the full lifting
force.
If overfilled, the thruster's internal pressure is impermissibly high.
The ELDRO
®
thrusters are filled correctly if the operating fluid level
reaches the lower edge within the filling opening when the thruster is
upright and the lifting rod is retracted.
Observe the disassembly instructions if the ELDRO
not installed upright (⇒ Disassembly chapter).
 Place the ELDRO
 Remove the filling screw from the filling nozzle.
 Check the fill level according to the ELDRO
required.
Figure 22:
Operating fluid fill height
1
Filling nozzle
2
Filling nozzle bottom edge (operating fluid fill height)
thruster may only opened at a maximum
®
thruster upright.
ELDRO-Assembly-manual-344029-EN.docx
®
thruster is
®
type and top up if

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents