Electrical Equipment - EMG ELDRO Ed 12/4 Assembly Manual

Electro-hydraulic lifting thrusters, standard range and special designs (three-phase voltage version)
Table of Contents

Advertisement

2
Safety
2.5

Electrical equipment

2.5
Electrical equipment
16 / 83
 Work on electrical equipment must be carried out exclusively by
electricians.
 When performing any work on electrical components, the five
safety rules must be adhered to:
– Disconnect from the electrical supply
– Safeguard to prevent a restart
– Test to ensure a de-energised state
– Earth and short-circuit
– Cover or isolate adjacent live parts
 Perform regular checks for insulation and housing damage.
 Never operate the ELDRO
that are faulty or not ready for operation.
 If there are power supply faults, the system must be switched off
immediately.
 Before any work on electrical components, switch the mains
disconnection thruster off and secure it to prevent it being switched
on again.
 It is essential to observe the inspection and maintenance intervals
specified by the manufacturer for electrical components.
 All touchable, conductive parts of the system are connected to the
external earthing conductor system. The earthing conductor
system must be inspected after performing maintenance work (e.g.
replacing components).
 Some equipment (e.g. mains power units, servo controllers,
converters) with electrical intermediate circuits may store residual
voltage for a certain time after being disconnected. Before starting
work on these systems, check that they are de-energised.
®
thruster with electrical connections
ELDRO-Assembly-manual-344029-EN.docx

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents