Adjusting The Valves; Adjustment Screw Installation Location - EMG ELDRO Ed 12/4 Assembly Manual

Electro-hydraulic lifting thrusters, standard range and special designs (three-phase voltage version)
Table of Contents

Advertisement

6.3

Adjusting the valves

6.3.1

Adjustment screw installation location

ELDRO-Assembly-manual-344029-EN.docx
In the condition as delivered, the ELDRO
seconds of setting time and resetting time. The setting times
depend on the temperature and must be adjusted when the
machine is at operating temperature.
The versions with lifting and/or lowering valves enable the lifting rod's
set or reset speed (setting or resetting time) to be adjusted infinitely
within a specific range. The type designation on the type plate
specifies whether an ELDRO
type plate; ⇒Type designation and type key section). The H (lifting
valve) and S (lowering valve) marks are embossed into the housing.
Examples for the version with valves:
 Lowering valve (S):
 Lifting valve (H):
 Lifting and lowering valve (HS): e.g. Ed 121/6 HS
All thrusters (apart from the Ed 630) can be equipped or
modified with valves retrospectively by the manufacturer.
The installation location for the adjustment screws is specified on the
dimensional drawings (⇒Dimensions section).
Adjustment screw H for the set time (lifting time) is located to the left
of the type plate below a sealing plug. See the "H" on the housing.
Adjustment screw S for the reset time (lowering time) is located to the
right of the type plate and is also below a sealing plug.
See the "S" on the housing.
Assembly and installation
Adjusting the valves
®
thrusters are set to 5
®
thruster is equipped with valves (see
e.g. Ed 50/6 S
e.g. Ed 80/6 H
6
6.3
63 / 83