C - "SUSPENDED LOAD" MODE
Providing a higher margin of safety, use with short
boom.
- Place the lift truck in the transport position.
- Press the
button for 2 seconds,
"SUSPENDED LOAD" MODE is validated by an
audible beep and the lighting of the lamp.
- Return to "HANDLING" MODE by pressing the
button.
• A1 - A2 - A3: There is a significant reserve of
longitudinal stability.
• A4 - A5: The lift truck is nearing the limit of longitudinal stability. The alarm sounds simultaneously with a very slow
intermittent sound. Move with care.
• A6: The lift truck is near at the limit of longitudinal stability. The alarm sounds with a slow intermittent sound. Move
with care.
• A7: The lift truck is very near at the limit of longitudinal stability. The alarm sounds with a fast intermittent sound.
Move with extreme care.
• A8: The lift truck is at the authorized limit of longitudinal stability. The alarm sounds with a very fast intermittent
sound. All "AGGRAVATING" hydraulic movements are cut-off. Cut-off may be preceded by an automatic slowing
of the hydraulic movement. Only make de-aggravating hydraulic movements in the following order: retract and
raise the boom.
NOTE: When the boom is retracted, the switch off "AGGRAVATING" hydraulic movements function is disconnected.
D - DISABLING "AGGRAVATING" HYDRAULIC MOVEMENT CUT-OFF
Remain very vigilant during this operation. The only information available to the operator is the lift truck's dynamic
In certain cases, in order to get out of a difficult situation, the operator can bypass this
safety system. Button D temporarily disables the cutting-off of "AGGRAVATING" hydraulic
movements.
- Hold down button D, lamp D1 will light, and at the same time and with extreme
care, carry out the required "AGGRAVATING" hydraulic movement. The combined
use of these two actions is limited to 60 seconds.
E - TESTING OF THE LONGITUDINAL STABILITY LIMITER AND WARNING DEVICE
- Short press the
alarm is working.
• Correct operation: All the LEDs light for two seconds and an audible beep
NOTE: This test does not check the proper adjustment of the longitudinal stability
limiter that must be inspected daily or after every 10 hours of service (see:
3 - MAINTENANCE: A - DAILY OR EVERY 10 HOURS SERVICE).
F - FAULT INDICATOR LAMP
The
warning indicator and a beep indicate a fault.
- To view this error code (see: 2 - DESCRIPTION: 3B - SCREEN DISPLAY).
G - STRAIN GAUGE
Disassembly or calibration of the strain gauge is prohibited, this must only be done by specially trained personnel,
IMPORTANT
stability.
button to verify at any time that the longitudinal stability
is sounded.
IMPORTANT
consult your dealer.