REPLACING THE DISTRIBUTOR CONTROL HEAD FILTER
Be careful to mount the filter 6 in the same direction as the arrow.
- Remove the half clamp 4.
- Undo the two couplings 5 and replace the filter 6.
- Refit half clamp 4.
FILLING UP THE OIL
- Clean and refit the drain plugs 1 (tightening torque 29 to 39 N.m).
- Fill up with oil (see: 3 - MAINTENANCE: LUBRICANTS AND FUEL) through filler port 7.
- Observe the oil level on dipstick 8, the oil level should be at the level of the red point.
- Check for any possible leaks at the drain plugs.
- Replace filler plug with a new filler plug 2 (see: 3 - MAINTENANCE: FILTERS CARTRIDGES
AND BELTS).
HYDRAULIC CIRCUIT DECONTAMINATION
- This should be carried out by your dealer after each oil change.
- The hydraulic oil used in the circuit must be at least equal in quality to class 8
(according to NAS 1638). Your dealer will be able to clean the hydraulic circuit using
an external unit and check the quality of the oil in order to ensure the long life of
hydraulic components and particularly of the main pump.
F9 – AIR CONDITIONING (OPTION)
CLEANING CONDENSER AND EVAPORATOR COILS (*)
CLEANING CONDENSATE TRAY AND RELIEF VALVE (*)
COLLECTING COOLANT TO REPLACE FILTER-DRIER (*)
REFILLING WITH COOLANT AND CHECKING THE THERMOSTATIC CONTROL AND PRESSURE SWITCHES (*)
NOTE: When opening the evaporator unit, remember to replace the cover seal.
DO NOT ATTEMPT TO REPAIR ANY FAULTS BY YOURSELF. ALWAYS REFER TO YOUR DEALER WHEN REFILLING CIRCUITS, AS THEY HOLD THE CORRECT SPARE PARTS,
In the event of inhalation, take the victim into fresh air, give oxygen or artificial respiration if necessary and call a doctor.
In the event of contact with the skin, wash immediately with copious amounts of water and remove any contaminated garments.
- Do not open the circuit under any circumstances as this would loss of coolant.
- The cooling circuit contains a gas which can be dangerous under certain conditions. This gas, coolant R-134a, is colorless,
odorless and heavier than air.
- The compressor has a fluid level gage; never unscrew this gage because it would
depressurize the system. The fluid level should only be checked when draining
the system.
IMPORTANT
IMPORTANT
AS WELL AS HAVING THE NECESSARY TECHNICAL KNOWLEDGE AND TOOLS.
In the event of contact with the eyes, rinse with clear water for 15 minutes and call a doctor.