A7 – LONGITUDINAL STABILITY LIMITER AND WARNING DEVICE
Use the test button
If in doubt during the test procedure, exit cleanly by short pressing the "BUCKET"
These tests are essential for checking correct operation and adjustment of the various system components.
- Place the lift truck on flat, level ground with the wheels straight.
- Hold down the test button.
STEP
1
1
- A beep.
- First green LED flashing.
- Test button lit.
STEP
2
2
1
- First green LED continuously lit.
- Second green LED flashing.
- Test button lit.
3
STEP
2
3
1
- First and second green LEDs
continuously lit.
- Third green LED flashing.
- Test button lit.
STEP 4
- The fault warning light remains
permanently on until the error is
repaired.
IMPORTANT
only when requested to do so, applying short presses (less than 1 second) and long presses (5 seconds) as instructed.
- Place the lif t truck with no
attachment, with the boom fully
retracted and raised.
- Lower with the engine running at
full revs and the hydraulic control at
the maximum setting. Slow the rate
of descent until movement is cut-off.
- Lower the boom until the movement
is cut off.
- Request, in the following order: a
reverse tilt, a forward tilt (dumping)
and a telescope extension. None
of these 3 movements should be
possible.
- The warning indicator lamp
- To view this error code (see: 2 - DESCRIPTION: 3B - SCREEN DISPLAY).
NOTE: A faulty fuse can generate several error codes. If this is the case, check the fuses (see: 2 - DESCRIPTION:
11 - FUSES AND RELAYS IN THE CAB).
- If error codes 520499, 520742, 520743 or 520754 are displayed, adjusting the longitudinal stability limiter and
warning device may solve the problem (see: 3 - MAINTENANCE: G - OCCASIONAL MAINTENANCE).
NOTE: For the stage 3 test, specify the non-conforming aggravating hydraulic movements, if necessary.
or "SUSPENDED LOAD"
Short
press
the test
button.
Short press
the test
button.
Short press
the test
button.
and a beep indicate a fault.
3 - 12
CHECK
MODE buttons.
TEST OK
- Beeps once and progresses to stage 2.
TEST NOT OK
- Beeps twice and warning indicator lamp
comes on.
- Exit test mode.
- Go to stage 4.
TEST OK
- Beeps once and progresses to stage 3.
TEST NOT OK
- Beeps twice fault indicator lamp
comes on.
- Exit test mode.
- Go to stage 4.
TEST OK
- Conformity of aggravating movement
cut-off.
- Exit test mode. All the LEDs will light for
2 seconds and a beep will be sounded.
TEST NOT OK
- Fault indicator lamp
comes on.
- Exit test mode.
- Go to stage 4.