3.1.5 The output is foggy horizontally.

3.1.6 The output has fuzzy, black horizontal lines.

General conditions
1) Execute 'PRINT test'. Is the output image normal? (See 3.21.5 of
YES: Go through steps 4) to 8).
NO:
Transfer guide assembly
2) Clean the transfer guide assembly. Is the problem corrected?
YES: End.
Drum unit, Developing unit
3) Try replacing the drum unit. Is the fault corrected?
YES: End.
NO:
Selfoc lens array (contact sensor)
4) Clean the selfoc lens array of the contact sensor. (See 4.3.1 of Chap-
YES: End.
Contact sensor LED intensity auto adjustment
5) Execute contact sensor LED intensity auto adjustment. Is the prob-
YES: End.
Connector
6) Is the connection of the following connectors normal: J501 and
NO:
Contact sensor
7) Try replacing the contact sensor. Is the problem corrected?
YES: End.
Analog processor PCB, Image processor PCB
8) Try replacing the analog processor PCB. Is the problem corrected?
YES: End.
NO:
COPYRIGHT © 2002 CANON INC.
Chapter 2.)
Go through steps 2) to 3).
Replace the developing unit.
ter 6.)
lem corrected? (See 1.2.4.1 of Chapter 7.)
J503 on the analog processor PCB; J317 on the image processor
PCB; and J504 of the contact sensor?
Connect them firmly. If the flexible cable has a scratch, replace it.
Replace the image processor PCB.