2.8.2.2 Removing the Original Pickup roller/Original Separation roller
1) Remove the separation roller unit. (See
2.8.2.1)
2) Free the 2 hooks [1], and detach the
original pickup roller [2].
3) Free the 2 hooks [3], and detach the
original separation roller [4].
2.8.2.3 Removing the Original Sensor/Registration Sensor
1) Remove the ADF motor unit. (See
2.8.1.3)
2) Free the 2 hooks [1], and detach the
original sensor [2].
3) Free the 2 hooks [3], and detach the reg-
istration sensor [4].
COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON iR1200/iR1300 Series REV. 0 AUG. 2002
CHAPTER 5 MECHANICAL SYSTEM
[2]
[1]
[3]
F05-208-16
[2]
F05-208-17
[1]
[3]
[4]
[1]
[3]
[4]
5-67