2.8.2.2 Removing the Original Pickup roller/Original Separation roller

1) Remove the separation roller unit. (See
2.8.2.1)
2) Free the 2 hooks [1], and detach the
original pickup roller [2].
3) Free the 2 hooks [3], and detach the
original separation roller [4].

2.8.2.3 Removing the Original Sensor/Registration Sensor

1) Remove the ADF motor unit. (See
2.8.1.3)
2) Free the 2 hooks [1], and detach the
original sensor [2].
3) Free the 2 hooks [3], and detach the reg-
istration sensor [4].