Carrier AquaForce 30XA Series Installation Instructions Manual page 3

Air-cooled liquid chillers
Hide thumbs Also See for AquaForce 30XA Series:
Table of Contents

Advertisement

30XA – AquaForce® Air-Cooled Chiller
Design Series
Unit Sizes*
080 102
140
182
240
282
350
082 110
142
200
242
300
352
090 112
160
202
260
302
400
092 120
162
220
262
325
401
100 122
180
222
280
327
450
Voltage
1 – 575-3-60
6 – 460-3-60
2 – 380-3-60
7 – 200-3-60
4 – 230-3-60
Condenser Coil/Ambient/Low Sound Options
- – Aluminum Fin/Copper Tube, High Ambient Temperature
0 – Copper Fin/Copper Tube, High Ambient Temperature
1 – Aluminum Pre-Coat Fin/Copper Tube, High Ambient Temperature
2 – Aluminum E-Coat Fin/Copper Tube, High Ambient Temperature
3 – Copper E-Coat Fin/Copper Tube, High Ambient Temperature
4 – Novation® Heat Exchanger (MCHX), High Ambient
Temperature
5 – MCHX E-Coat, High Ambient Temperature
6 – Aluminum Fin/Copper Tube, High Ambient Temperature,
Low Sound
7 – Copper Fin/Copper Tube, High Ambient Temperature, Low Sound
8 – Aluminum Pre-Coat Fin/Copper Tube, High Ambient Temperature,
Low Sound
9 – Aluminum E-Coat Fin/Copper Tube, High Ambient Temperature,
Low Sound
B – Copper E-Coat Fin/Copper Tube, High Ambient Temperature,
Low Sound
C – MCHX, High Ambient Temperature, Low Sound
D – MCHX E-Coat, High Ambient Temperature, Low Sound
F – Aluminum Fin/Copper Tube, Standard Ambient Temperature,
Low Sound
G – Copper Fin/Copper Tube, Standard Ambient Temperature,
Low Sound
H – Aluminum Pre-Coat Fin/Copper Tube, Standard Ambient
Temperature, Low Sound
J – Aluminum E-Coated Fin/Copper Tube, Standard Ambient
Temperature, Low Sound
K – Copper E-Coat Fin/Copper Tube, Standard Ambient Temperature,
Low Sound
L – MCHX, Standard Ambient Temperature, Low Sound
M – MCHX E-Coat, Standard Ambient Temperature, Low Sound
N – Aluminum Fin/Copper Tube, Standard Ambient Temperature
P – Copper Fin/Copper Tube, Standard Ambient Temperature
Q – Aluminum Pre-Coat Fin/Copper Tube, Standard Ambient
Temperature
R – Aluminum E-Coat Fin/Copper Tube, Standard Ambient
Temperature
S – Copper E-Coat Fin/Copper Tube, Standard Ambient Temperature
T – MCHX, Standard Ambient Temperature
V – MCHX E-Coat, Standard Ambient Temperature
Hydronic Pump Package Options
- – None
G – Single Pump, 5 HP with VFD
1 – Single Pump, 5 HP
H – Single Pump, 7.5 HP with VFD
2 – Single Pump, 7.5 HP
J – Single Pump, 10 HP with VFD
3 – Single Pump, 10 HP
K – Single Pump, 15 HP with VFD
4 – Single Pump, 15 HP
N – Dual Pump, 5 HP with VFD
7 – Dual Pump, 5 HP
P – Dual Pump, 7.5 HP with VFD
8 – Dual Pump, 7.5 HP
Q – Dual Pump, 10 HP with VFD
B – Dual Pump, 10 HP
R – Dual Pump, 15 HP with VFD
C – Dual Pump, 15 HP
Cooler Options
- – Integral DX Cooler without Heater
0 – Integral Cooler with Heater†
1 – Integral DX Cooler with Heater, Hydronic Package
3 – Integral Flooded Cooler with Heater, Minus One Pass
5 – Integral Flooded Cooler with Heater, Plus One Pass
6 – Integral DX Cooler without Heater, Hydronic Package
7 – Integral Cooler with Heater, Full End Screen, Coil Trim Panels, Grilles†
8 – Integral DX Cooler with Heater, Hydronic Package, Full End Screen,
Coil Trim Panels, Grilles
F – Integral DX Cooler without Heater, Hydronic Package, Full End Screen,
Coil Trim Panels, Grilles
G – Integral DX Cooler without Heater, Full End Screen, Coil Trim Panels, Grilles
K – Integral Flooded Cooler with Heater, Minus One Pass, Full End Screen,
Coil Trim Panels, Grilles
M – Integral Flooded Cooler with Heater, Plus One Pass, Full End Screen,
Coil Trim Panels, Grilles
LEGEND
CFSP
Face Shipping Protection
EMM
Energy Management Module
LON
Local Operating Network
SCCR
Short Circuit Current Rating
XL
Across-the-Line Starter
* xx0, xx1, xx5, and xx6 size units contain flooded style coolers.
xx2 and xx7 size units contain direct expansion (DX) style coolers.
† Both flooded and DX cooler.
A
451
476
500
501
Fig. 1 — AquaForce
®
Chiller Model Number Designation
Packaging/Security Options
0 – Coil Face Shipping Protection (CFSP), Skid
1 – CFSP, Skid, Top Crate, Bag
3 – CFSP, Coil Trim Panels
4 – CFSP, Skid, Coil Trim Panels
5 – CFSP, Skid, Top Crate, Bag, Coil Trim Panels
7 – CFSP, Coil Trim Panels, Upper and Lower Grilles
8 – CFSP, Skid, Coil Trim Panels, Upper and Lower Grilles
9 – CFSP, Skid, Top Crate, Bag, Coil Trim Panels, Upper and Lower Grilles
C – CFSP, Coil Trim Panels, Upper and Lower Grilles, Upper Hail Guards
D – CFSP, Skid, Coil Trim Panels, Upper and Lower Grilles, Upper Hail Guards
F – CFSP, Skid, Top Crate, Bag, Coil Trim Panels, Upper and Lower Grilles,
Upper Hail Guards
H – CFSP, Skid, High SCCR
J – CFSP, Skid, Top Crate, Bag, High SCCR
K – CFSP, High SCCR
L – CFSP
M – CFSP, Coil Trim Panels, High SCCR
N – CFSP, Skid, Coil Trim Panels, High SCCR
P – CFSP, Skid, Top Crate, Bag, Coil Trim Panels, High SCCR
R – CFSP, Coil Trim Panels, Upper and Lower Grilles, High SCCR
S – CFSP, Skid, Coil Trim Panels, Upper and Lower Grilles, High SCCR
T – CFSP, Skid, Top Crate, Bag, Coil Trim Panels, Upper and Lower Grilles,
High SCCR
W – CFSP, Coil Trim Panels, Upper and Lower Grilles, Upper Hail Guards, High SCCR
X – CFSP, Skid, Coil Trim Panels, Upper and Lower Grilles, Upper Hail Guards,
High SCCR
Y – CFSP, Skid, Top Crate, Bag, Coil Trim Panels, Upper and Lower Grilles, Upper
Hail Guards, High SCCR
Controls/Communication Options
- – Navigator™ Display
0 – Navigator Display, EMM
1 – Navigator Display, Service Option
2 – Navigator Display, EMM, Service Option
3 – Touch Pilot™ Display
4 – Touch Pilot Display, EMM
5 – Touch Pilot Display, Service Option
6 – Touch Pilot Display, EMM, Service Option
7 – Navigator Display, BACnet Translator
8 – Navigator Display, BACnet Translator, EMM
9 – Navigator Display, BACnet Translator, Service Option
B – Navigator Display, BACnet Translator, EMM, Service Option
C – Touch Pilot Display, BACnet Translator
D – Touch Pilot Display, BACnet Translator, EMM
F – Touch Pilot Display, BACnet Translator, Service Option
G – Touch Pilot Display, BACnet Translator, EMM, Service Option
H – Navigator Display, LON Translator
J – Navigator Display, LON Translator, EMM
K – Navigator Display, LON Translator, Service Option
L – Navigator Display, LON Translator, EMM, Service Option
M – Touch Pilot Display, LON Translator
N – Touch Pilot Display, LON Translator, EMM
P – Touch Pilot Display, LON Translator, Service Option
Q – Touch Pilot Display, LON Translator, EMM, Service Option
R – Navigator Display, BACnet Communication
S – Navigator Display, BACnet Communication, EMM
T – Navigator Display, BACnet Communication, Service Option
V – Navigator Display, BACnet Communication, EMM, Service Option
W – Touch Pilot Display, BACnet Communication
X – Touch Pilot Display, BACnet Communication, EMM
Y – Touch Pilot Display, BACnet Communication, Service Option
Z – Touch Pilot Display, BACnet Communication, EMM, Service Option
Electrical Options
- – Single Point Power, XL, Terminal Block, No Control Transformer
0 – Single Point Power, Wye-Delta, Terminal Block, No Control Transformer
3 – Dual Point Power, XL, Terminal Block, No Control Transformer
4 – Dual Point Power, Wye-Delta, Terminal Block, No Control Transformer
7 – Single Point Power, XL, Disconnect, No Control Transformer
8 – Single Point Power, Wye-Delta, Disconnect, No Control Transformer
C – Dual Point Power, XL, Disconnect, No Control Transformer
D – Dual Point Power, Wye-Delta, Disconnect, No Control Transformer
H – Single Point Power, XL, Terminal Block, Control Transformer
J – Single Point Power, Wye-Delta, Terminal Block, Control Transformer
M – Dual Point Power, XL, Terminal Block, Control Transformer
N – Dual Point Power, Wye-Delta, Terminal Block, Control Transformer
R – Single Point Power, XL, Disconnect, Control Transformer
S – Single Point Power, Wye-Delta, Disconnect, Control Transformer
W – Dual Point Power, XL, Disconnect, Control Transformer
X – Dual Point Power, Wye-Delta, Disconnect, Control Transformer
Refrigeration Circuit Options
- – None
0 – Suction Line Insulation
1 – Isolation Valves
2 – Low Ambient Head Pressure Control
3 – Suction Line Insulation, Isolation Valves
4 – Suction Line Insulation, Low Ambient Head Pressure Control
5 – Isolation Valves, Low Ambient Head Pressure Control
6 – Suction Line Insulation, Isolation Valves, Head Pressure Control
7 – Minimum Load Control
8 – Suction Line Insulation, Minimum Load Control
9 – Isolation Valves, Minimum Load Control
B – Low Ambient Head Pressure Control Operation, Minimum Load Control
C – Suction Line Insulation, Isolation Valves, Minimum Load Control
D – Suction Line Insulation, Head Pressure Control, Minimum Load Control
F – Isolation Valves, Head Pressure Control, Minimum Load Control
G – Suction Line Insulation, Isolation Valves, Head Pressure Control, Minimum Load Control
3
a30-5476