Carrier AquaForce 30XA Series Installation Instructions Manual page 148

Air-cooled liquid chillers
Hide thumbs Also See for AquaForce 30XA Series:
Table of Contents

Advertisement

Table 6 — 30XA080-500 Electrical Data, Dual Point (Standard Condenser Fan Motors) (cont)
UNIT VOLTAGE
UNIT
Supplied
V-Hz
30XA
(3 Ph)
Min
Max
230-60
207
253
200-60
187
220
080,
460-60
414
506
082
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
090,
460-60
414
506
092
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
100,
460-60
414
506
102
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
110,
460-60
414
506
112
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
120,
460-60
414
506
122
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
140,
460-60
414
506
142
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
160,
460-60
414
506
162
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
180,
460-60
414
506
182
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
200,
460-60
414
506
202
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
220,
460-60
414
506
222
575-60
518
633
380-60
342
418
230-60
207
253
200-60
187
220
240,
460-60
414
506
242
575-60
518
633
380-60
342
418
460-60
414
506
260,
575-60
518
633
262
380-60
342
418
460-60
414
506
280,
575-60
518
633
282
380-60
342
418
460-60
414
506
300,
575-60
518
633
302
380-60
342
418
460-60
414
506
325,
575-60
518
633
327
380-60
342
418
460-60
414
506
350,
575-60
518
633
352
380-60
342
418
460-60
414
506
400
575-60
518
633
380-60
342
418
LEGEND
ICF
— Instantaneous Current Flow
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
WD
— Wye-Delta
XL
— Across-the-Line
NUMBER
OF
COND
MCA
MOCP
FANS
3/3
3/3
3/3
3/3
3/3
4/4
182.9/227.9
300/350
4/4
201.5/251.2
300/350
4/4
91.4/113.9
150/175
4/4
70.3/ 88.3
110/125
4/4
106.5/133.7
175/200
4/4
199.9/244.9
300/350
4/4
220.0/269.8
350/400
4/4
99.9/122.4
150/175
4/4
76.4/ 94.4
125/125
4/4
116.5/143.8
175/225
4/4
241.0/244.9
400/350
4/4
264.9/269.8
450/400
4/4
120.0/122.4
200/175
4/4
92.5/ 94.4
150/125
4/4
140.2/143.8
225/225
4/4
241.0/286.0
400/450
4/4
264.9/314.7
450/500
4/4
120.0/142.5
200/225
4/4
92.5/110.5
150/175
4/4
140.2/167.5
225/250
6/4
370.0/244.9
600/350
6/4
407.2/269.8
700/400
6/4
185.0/122.4
300/175
6/4
141.9/ 94.4
225/125
6/4
215.1/143.8
350/225
6/4
423.5/286.0
700/450
6/4
465.6/314.7
800/500
6/4
211.3/142.5
350/225
6/4
162.2/110.5
250/175
6/4
246.0/167.5
400/250
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
7/6
9/6
9/6
9/6
9/7
9/7
9/7
10/6
10/6
10/6
9/9
9/9
9/9
9/9
9/9
9/9
8/12
8/12
8/12
15 HP PUMP, 3450 RPM
ICF
WD
348.0/393.0
1034.0/1079.0
399.5/449.3
1188.5/1238.3
174.0/196.5
517.0/ 539.5
139.6/157.6
413.6/ 431.6
210.5/237.8
625.5/ 652.8
372.0/417.0
1114.0/1159.0
426.5/476.3
1280.5/1330.3
186.0/208.5
557.0/ 579.5
148.6/166.6
445.6/ 463.6
225.5/252.8
674.5/ 701.8
372.0/417.0
426.5/476.3
186.0/208.5
557.0/ 579.5
148.6/166.6
445.6/ 463.6
225.5/252.8
674.5/ 701.8
372.0/417.0
426.5/476.3
186.0/208.5
557.0/ 579.5
148.6/166.6
445.6/ 463.6
225.5/252.8
674.5/ 701.8
632.0/417.0
724.8/476.3
316.0/208.5
948.0/ 579.5
252.4/166.6
758.4/ 463.6
382.8/252.8
1147.8/ 701.8
800.0/417.0
918.8/476.3
400.0/208.5
1208.0/ 579.5
320.4/166.6
966.4/ 463.6
483.8/252.8
1462.8/ 701.8
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
2. Cooler heater is wired into the control circuit so it is always operable as long as the control
power supply disconnect is on, even if any safety device is open.
3. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381 and 760 amps, 6 conductors are required.
For MCA between 761 and 1140 amps, 9 conductors are required.
For MCA between 1141 and 1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
4. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is 1/
0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
5. Data provided circuit 1/circuit 2 where there are two circuits.
6. Standard condenser fan motors are not used with sizes 30XA-401, 451, 476, and 501.
These sizes use high ambient temperature condenser fans.
148
CONTROL CIRCUIT
Rec
Voltage
Fuse
1 PH,
XL
Size
60 Hz
115
115
115
115
115
225/300
115
250/300
115
110/150
115
90/110
115
125/175
115
250/300
115
300/350
115
125/150
115
90/110
115
150/175
115
300/300
115
350/350
115
150/150
115
110/110
115
175/175
115
300/350
115
350/400
115
150/175
115
110/150
115
175/200
115
450/300
115
500/350
115
225/150
115
175/110
115
300/175
115
600/350
115
600/400
115
250/175
115
200/150
115
300/200
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
115
MCA
and
MOCP
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60