4-32
N P • 70
1)
AUTOMATIC TONER REPLENISHMENT (ATR) SUBASSEMBLY
The ATR Subassembly checks the developer density and initiates toner replenishment when-
ever the density falls below a certain level. Fig. 4-36 depicts the main components of this
subassembly.
Upper Cover
ATR Printed Circuit Board
Density Detector
Subassembly Housing
Fig. 4-36 ATR Subassembly Main Components
The ATR Subassembly operation is divided into two areas —mechanical and electronic. In this
section only the mechanical operation will be explained. For information about the electronic
operation, refer to Chapter 3 of this manual.
Second Printing-June, 1974
'C~
CANON
ANC.