4-105
Front Safety Lever
Pivot Shaft
(Front Door)
Fig. 4-123 Adjustment of Front Safety Lever
2) JAM STOP GROUP ADJUSTMENTS
In case of a paper jam, the reset button should be tripped at once, with the power to most
circuits being broken. Adjust the following:
a) Position of
SL7
When SL7 is ON, the stud of the trip release lever should come out of the notch of the
actuator trip lever; when SL7 is OFF, the trip release lever should be held firmly by the
stud. The position of SL7 should be adjusted so that it operates properly in the above
two situations; do this by loosening the retaining screws which secure SL7 and sliding the
solenoid up or down (see Fig. 4124).
b) Position of MS6A & MS6B
Microswitches
MS6A & MS6B should be turned ON securely when the reset button is
depressed. Adjust the position of the microswitches by loosening and sliding the adjust
screw (see Fig. 4-124).
Actuators
MS6A & MS6B
Adjust Screw
SL7
SL7 Retaining Screws
Ass'y Main Plate
Fig. 4-124 Jam Stop Group Adjustments