Section 2

Electrical Service

Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
n
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.

VOLTAGE

All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
The equipment must be grounded.
A separate fuse/circuit breaker must be provided for
each unit.
A qualified electrician must determine proper wire size
dependent upon location, materials used and length
of run (minimum circuit ampacity can be used to help
select the wire size).
The maximum allowable voltage variation is ±10% of
the rated voltage at equipment start-up (when the
electrical load is highest).
Check all green ground screws, cables and wire
connections to verify they are tight before start-up.

GROUND FAULT CIRCUIT INTERRUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power, presumably
to ground. Manitowoc does not recommend the use of
GFCI/GFI circuit protection to energize our equipment. If
code requires the use of a GFCI/GFI then you must follow
the local code. The circuit must be dedicated, sized
properly and there must be a panel GFCI/GFI breaker. We
do not recommend the use of GFCI/GFI outlets to energize
our equipment as they are known for more intermittent
nuisance trips than panel breakers.
These appliances will operate within the marked rated
voltage range without adjustment.
Part Number: 9291458 REV00 12/19
DANGER
Warning

Note
RATED AMPERAGES, HORSEPOWER, VOLTAGE &
POWER CORD CHART
Units with plugs are supplied with approximately 6ft
(183cm) cords.
Model
V, Hz, Ph
8100-EFP Series R290
8118-EFP
115, 60, 1
8132-EFP
115, 60, 1
8145-EFP
115, 60, 1
8159-EFP
115, 60, 1
8172-EFP
115, 60, 1
8186-EFP
115, 60, 1
8100-EF-E Export Series
8118-EF-E
8132-EF-E
8145-EF-E
230-240, 50, 1
8159-EF-E
8172-EF-E
8186-EF-E
8100-EFNP Series R290
8148-EFNP
8169-EFNP
115, 60, 1
8191-EFNP
8100-EFN-E Export Series
8148-EFN-E
8169-EFN-E
230-240, 50, 1
8191-EFN-E
N8000 Series - NA
N8000N Series - NA
N8000-R Series - NA
N8100BP Series - R290
N8118BP
115, 60, 1
N8130BP
115, 60, 1
N8143BP
115, 60, 1
N8156BP
115, 60, 1
N8169BP
115, 60, 1
N8181BP
115, 60, 1
N8100B-E Export Series - R404A
N8118B-E
N8130B-E
230-240, 50, 1
N8143B-E
N8100B-E Export Series - R134A
N8156B-E
230-240, 50, 1
N8169B-E
N8100BRP Series - R290
N8144-BRP
115, 60, 1
N8159-BRP
115, 60, 1
N8176-BRP
115, 60, 1
N8194-BRP
115, 60, 1
N8100-FAP Series - R290
N8131-FAP
115, 60, 1
N8144-FAP
115, 60, 1
N8157-FAP
115, 60, 1
N8169-FAP
115, 60, 1
N8182-FAP
115, 60, 1
N8100NB Series - R290
N8146NBP
115, 60, 1
N8168NBP
115, 60, 1
Installation
Amps
H.P.
Plug
2.4
1/5 NEMA 5-15P
2.4
1/5 NEMA 5-15P
3.7
1/4 NEMA 5-15P
3.7
1/4 NEMA 5-15P
4.8
1/3 NEMA 5-15P
4.8
1/3 NEMA 5-15P
2.5 Amps /
Varies Per
1/4
600 Watts
Destination
2.4
1/5
3.7
1/4
NEMA 5-15P
4.8
1/3
2.5 Amps /
Varies Per
1/4
600 Watts
Destination
2.0
1/5 NEMA 5-15P
2.0
1/5 NEMA 5-15P
3.1
1/4 NEMA 5-15P
3.1
1/4 NEMA 5-15P
3.1
1/4 NEMA 5-15P
4.6
1/3 NEMA 5-15P
1.5 Amps /
Varies Per
1/5
360 Watts
Destination
2.5 Amps /
Varies Per
1/4
600 Watts
Destination
2.4
1/5 NEMA 5-15P
3.7
1/4 NEMA 5-15P
3.7
1/4 NEMA 5-15P
3.7
1/4 NEMA 5-15P
4.7
1/4 NEMA 5-15P
4.7
1/4 NEMA 5-15P
9.3
1/2 NEMA 5-15P
9.3
1/2 NEMA 5-15P
9.3
1/2 NEMA 5-15P
2
1/5 NEMA 5-15P
3.1
1/4 NEMA 5-15P
29