Section 2

Electrical Service

Check all wiring connections, including factory terminals,
before operation. Connections can become loose during
shipment and installation.
Copper wire suitable for at least 167°F (75°C) must be
used for power connections.
n
This appliance must be grounded and all field wiring must
conform to all applicable local and national codes. Refer
to rating plate for proper voltage. It is the responsibility of
the end user to provide the disconnect means to satisfy
the authority having jurisdiction.

VOLTAGE

All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for each
unit.
• A qualified electrician must determine proper wire size
dependent upon location, materials used and length of
run (minimum circuit ampacity can be used to help select
the wire size).
• The maximum allowable voltage variation is ±10% of the
rated voltage at equipment start-up (when the electrical
load is highest).
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
Part Number: 9291465 06/17
DANGER
DANGER
Warning
RATED AMPERAGES, HORSEPOWER & VOLTAGE CHART
Taco Bueno Dual Line Electrical Rating:
120/208Y or 120/240Volts, 60Hz, 3Ph, 4 Wire, 200A
Component
Amps
Cold Food
10.0
Table
4 Heater
68.0/75.0
3 Heater
51.0/57.0

Drain Connections

n
If a refrigerated base does not have a condensate
evaporator supplied, you must connect the condensate
line to a suitable drain. Otherwise, water will collect on
the floor, causing a potentially hazardous situation.
n
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owner's responsibility to provide a container or
outlet for drainage.

Refrigeration

Component
BTU/Hour
Capacity
Base
Cold Food
2200
Table
Installation
HP
Voltage, Hertz,
Phase
1/4
115, 60, 1
120/208Y-240,
NA
60, 1
120/208Y-240,
NA
60, 1
Warning
Warning
Heat of
Rejection
Rail
Base
Rail
1432
461
810
Watts
1150
14,000
10,500
R404A
Charge
16oz
9