Delfield 8100-EFP Series Installation, Operation And Maintenance Manual page 33

Drop ins
Table of Contents

Advertisement

Section 2
APPLICABLE TO N8700 MODELS
1. Locate mounting holes on outside operator drop-in body and mount float and bracket using thumb screws.
2. Install drain plumbing as shown.
3. Connect clear plastic tubing to 1/2" copper stub and connect to the float. Use hose clamps to secure.
4. Connect fill line to 1/4" compression fitting.
5. Loosen thumb screws to achieve desired water level.
Part Number: 9291458 REV00 12/19
Installation
NO CONNECTION
NEEDED
33