8100-EFP, N8000, N8000N, N8000-R, N8100BP,
N8100-BRP, N8100-FAP, N8200P, N8200GP, N8200-
STP, N8600P, N8700-D, N8700-DESP, N8700-R, N8800
Installation, Operation and Maintenance Manual
Caution
,
Read this instruction before operating this equipment.
Original Document
Part Number 9291458 Rev00 11/19

Advertisement

Table of Contents
loading

Summary of Contents for Delfield 8100-EFP Series

  • Page 1 Fresh Solutions, Fit For You Drop Ins 8100-EFP, N8000, N8000N, N8000-R, N8100BP, N8100-BRP, N8100-FAP, N8200P, N8200GP, N8200- STP, N8600P, N8700-D, N8700-DESP, N8700-R, N8800 Installation, Operation and Maintenance Manual Caution Read this instruction before operating this equipment. Original Document Part Number 9291458 Rev00 11/19...
  • Page 2 Safety Notices Warning This product contains chemicals known to the State Warning of California to cause cancer and/or birth defects or Read this manual thoroughly before operating, installing other reproductive harm. Operation, installation, and or performing maintenance on the equipment. Failure servicing of this product could expose you to airborne to follow instructions in this manual can cause property particles of glasswool or ceramic fibers, crystalline...
  • Page 3: Table Of Contents

    Table of Contents Section 1 General Information Model Numbers ........................5 Serial Number Location ..................... 6 Warranty Information ......................6 Regulatory Certifications ....................6 Domestic Models ............................6 Export Models ............................6 Section 2 Installation Location ..........................8 Weight Of Equipment ......................8 Dimensions ........................10 Clearance Requirements ....................12 Cutout Installation Dimensions ..................13...
  • Page 4 Table of Contents (continued) N8700-DESP Operation....................41 Section 4 Maintenance Cleaning and Sanitizing Procedures ................42 General ..............................42 Exterior Cleaning ..........................43 Cleaning the Condenser Coil ......................43 N8100-FA Series Drain Maintenance .................... 43 Part Number: 9291458 REV00 11/19...
  • Page 5: General Information

    Section 1 General Information Model Numbers N8200P Series Self-Contained Frost Tops - R290 8100-EFP Series N8231P N8245P N8259P LiquiTec® Eutetic Fluid Refrigerated Cold Pans - R290 N8273P N8287P 8118-EFP 8132-EFP 8145-EFP N8200-E Export Series 8159-EFP 8172-EFP 8186-EFP Self-Contained Frost Tops - R404A...
  • Page 6: Serial Number Location

    EXPORT MODELS • Verify warranty information, All export models are certified by: • View and download a copy of your warranty, • National Sanitation Foundation (NSF) at www.delfield.com/warranty • Technical Inspection Association • European Conformity Part Number: 9291458 REV00 11/19...
  • Page 7: Installation

    Warning If the LiquiTec unit cold pans leak, immediately call the Delfield service department directly at 1-800-733-8821 If a refrigerated base does not have a condensate not your local service agent.
  • Page 8: Location

    Installation Section 2 Location Weight Of Equipment The location selected for the equipment must meet the Model Ship Weight 8100-EFP Series following criteria. If any of these criteria are not met, select 8118-EFP 169lbs (77kg) another location. 8132-EFP 215lbs (98kg) •...
  • Page 9 Section 2 Installation Model Ship Weight Model Ship Weight N8100-FAP Series N8700DESP Series N8131-FAP 168lbs (76kg) N8717-DESP 41lbs (19kg) N8144-FAP 175lbs (79kg) N8731-DESP 99lbs (45kg) N8157-FAP 225lbs (102kg) N8745-DESP 134lbs (61kg) N8169-FAP 235lbs (107kg) N8759-DESP 166lbs (75kg) N8182-FAP 406lbs (184kg) N8773-DESP 186lbs (84kg) N8100NBP Series...
  • Page 10: Dimensions

    Section 2 Dimensions Model Length Depth Height 12x20 Pans Model Length Depth Height 12x20 N8000N Series Pans N8046N 46.75“ 18“ 10.75“ 8100-EFP Series (119cm) (46cm) (27cm) 8118-EFP 18.20” 26” 23.25” N8068N 67.5“ 18“ 10.75“ (46cm) (66cm) (59cm) (171cm) (46cm) (27cm) 8132-EFP 31.76”...
  • Page 11 Section 2 Installation Model Length Depth Height 12x20 Model Length Depth Height 12x20 Pans Pans N8100NBP Series N8600P Series N8146NBP 46.75” 18” 21.81” N8630P 30.75” 26” 23.75” (119cm) (46cm) (55cm) (78cm) (66cm) (60cm) N8168NBP 67.5” 18” 21.81” N8643P 43.5” 26” 23.75”...
  • Page 12: Clearance Requirements

    Installation Section 2 Clearance Requirements Model Length Depth Height 12x20 Pans N8700-D-ESP-E Export Series DANGER N8717-D-ESP-E 17.89” 26” 9.5” Minimum clearance requirements are the same for (45cm) (66cm) (24cm)* noncombustible locations as for combustible locations. N8731-D-ESP-E 31.76” 26” 9.5” The flooring under the appliance must be made of a (81cm) (66cm) (24cm)*...
  • Page 13: Cutout Installation Dimensions

    Dimensions Dimensions Model Counter Cutout Control Panel Cutout N8000N Series Dimensions Dimensions 45.75” x 17” N8046N 8100-EFP Series (116cm x 43cm) 8118-EFP 17” x 25” 66.50” x 17” N8068N (43cm x 64cm) (169cm x 43cm) 8132-EFP 30.75” x 25” N8000-R Series...
  • Page 14 Installation Section 2 Model Counter Cutout Control Panel Cutout Model Counter Cutout Control Panel Cutout Dimensions Dimensions Dimensions Dimensions N8100FAP Series N8200G-E Export Series N8131-FAP 30.25” x 25.5” N8231G-E 30.75” X 25” (77cm x 65cm) (78cm x 64cm) N8144-FAP 43” x 25.5” N8245G-E 44.63”...
  • Page 15 Section 2 Installation Model Counter Cutout Control Panel Cutout Model Counter Cutout Control Panel Cutout Dimensions Dimensions Dimensions Dimensions N8700DESP Series N8800-E Export Series N8717-DESP 16.87” X 25” 5” x 6.88” x 7.50” N8831-E 30.75” X 25” 12.25” x 4.25” x 7” (78cm x 64cm) (31cm x 11cm x 18cm) (43cm x 64cm)
  • Page 16: Curved Drop-In Cutout Details

    Installation Section 2 CURVED DROP-IN CUTOUT DETAILS 19.75” 19.75” 2 pan standard curved drop-in cutout detail 50cm 50cm for models: • N8044-R 172.50˚ 85˚ 85˚ • N8144-BRP 2-PAN STD. 25.00” 25.00” • N8744-R 25.10” 25.10” 64cm 64cm RADIAL DROP-IN 64cm 64cm CUTOUT DETAIL 95˚...
  • Page 17: Drop-In Counter Installation

    Section 2 Installation Drop-In Counter Installation 1. Place the ice cooled drop-in unit through the counter cutout. ICE COOLED DROP-IN UNITS 2. A gasket is installed in the flange of each unit. N8000, N8000N, N8000-R The weight of the unit on the gasket forms a seal preventing liquids from seeping into the cut-out opening.
  • Page 18: 8100P Series Self-Contained Refrigerated Drop-In Units

    Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8100-EFNP, N8100BP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use.
  • Page 19 Section 2 Installation the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty. • Louver measures 13.00” x 25.00” (33cm x 64cm). • Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm) (typical installation).
  • Page 20 Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8100BRP, N8100-EFP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use.
  • Page 21 Section 2 Installation the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty. • Louver measures 13.00” x 25.00” (33cm x 64cm). • Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm) (typical installation).
  • Page 22: 8100P Series Forced-Air Refrigerated Drop-In Units

    Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8100-FAP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use.
  • Page 23 Section 2 Installation the 1” diameter drain on N8100-FAP models is shipped loose and must be connected during installation. Perforated Pan Clip Black Air ow Extrusions N8157-FAP, N8169-FAP and N8182-FAP have two 1” drains. A. Provided 1” (25mm) drain, nut and washer must Adapter Bars be field installed to an appropriate container or floor drain following local code requirements.
  • Page 24: 8200P Series Self-Contained Refrigerated Drop-In Units

    Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8200P, N8200-GP, N8200-STP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use 2.
  • Page 25 Section 2 Installation C. Apply thin ring of plumbers putty around the drain. D. From the inside drop the drain into the drain hole. Use Screws to Secure Desired Depth 3 of 8 Screws Shown 6. Partitions must fully extend front to back and top to bottom.
  • Page 26: 8600P Self-Contained Combo Hot/Cold Drop-In Units

    Installation Section 2 SELF-CONTAINED COMBO HOT/COLD DROP-IN UNITS N8600P For any non-standard installation consult the factory. 1. Cabinet interior minimum dimensions: Dimension N8630P N8643P N8656P 29.75"/76cm 42.5"/108cm 55.25"/140cm 29"/74cm 29"/74cm 29"/74cm 28"/71cm 28"/71cm 28"/71cm 29.75"/76cm 42.5"/108cm 55.5"/140cm 25"/64cm 25"/64cm 25"/64cm 4.75”/12cm Min.
  • Page 27 Section 2 Installation NOTE: CONT: the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty. • Louver measures 20.00” x 25.00” (51cm x 64cm). • Louver Cutout Size is 18.50” x 22.50” (47cm x 57cm) (typical installation).
  • Page 28: 8700 Hot Food Well Drop-In Units

    Installation Section 2 HOT FOOD WELL DROP-IN UNITS 1. Orient the control panel with the indicator light for each control to the right of the control. N8700-D, N8700-DESP, N8700N, N8700-R, N8800 • N8700 series units have 48” (122cm) of conduit. •...
  • Page 29: Electrical Service

    Check all wiring connections, including factory terminals, before operation. Connections can become Model V, Hz, Ph Amps H.P. Plug loose during shipment and installation. 8100-EFP Series R290 8118-EFP 115, 60, 1 1/5 NEMA 5-15P 8132-EFP 115, 60, 1 1/5 NEMA 5-15P Warning...
  • Page 30 Installation Section 2 Model V, Hz, Ph Amps H.P. Plug Model V, Hz, Ph Amps H.P. Plug N8100NB-E Export Series N8700D-E Export Series N8146NB-E N8717-D-E 240, 50, 1 6.0 Amps / Hard Wire Varies Per 1.5 Amps / 230-240, 50, 1 N8168NB-E 1450 Watts 360 Watts...
  • Page 31: Refrigeration

    N8231P 30/26º/-17° 120g Model BTU Load Evap BTU/TD/ Sys Cap Refrig. N8245P 46/19º/-10° 120g TEMP Charge N8259P 1208 63/20º/-11° 1274 120g 8100-EFP Series N8273P 1539 78/17º/-8° 1358 120g 8118-EFP 12/55º/-20° 120g N8287P 1871 95/19º/-10° 1776 150g 8132-EFP 22/42º/-7° 120g N8200-E Export Series 8145-EFP 31/43º/-8°...
  • Page 32: Optional Auto Fill Installation

    Installation Section 2 Optional Auto Fill Installation • Option is a loose parts kit. Installation requires a plumber. APPLICABLE TO N8600 & N8800 MODELS 1. Locate mounting holes on outside operator drop-in body and mount float and bracket using thumb screws. 2.
  • Page 33 Section 2 Installation APPLICABLE TO N8700 MODELS 1. Locate mounting holes on outside operator drop-in body and mount float and bracket using thumb screws. 2. Install drain plumbing as shown. 3. Connect clear plastic tubing to 1/2” copper stub and connect to the float. Use hose clamps to secure. 4.
  • Page 34: Operation

    Section 3 Operation Product Quality in Cold Pans DANGER The on-site supervisor is responsible for ensuring that Warning operators are made aware of the inherent dangers of The operator of this equipment is solely responsible operating this equipment. for ensuring safe holding temperature levels for all food items.
  • Page 35: 8100-Ef(N)P Series Operation

    8100-EFP units on and off. The unit must be turned off when not in use or overnight for defrosting and cleaning. 8100-EFP Series LiquiTec® Eutetic fluid cold pans are Operation / Indication adjusted at the factory to provide proper operation without...
  • Page 36: Changing Display From Fahrenheit To Celsius On Erc112 Control

    Operation Section 3 Press upper or lower right button. CHANGING DISPLAY FROM FAHRENHEIT TO CELSIUS ON ERC112 CONTROL • Display show actual set-point (blinking). 1. Simultaneously hold the up and down arrows for • If buttons untouched for 3 seconds returns to 5 seconds to access menu for password protected normal.
  • Page 37: N8100Bp, N8100-Brp & N8100Nbp Operation

    Section 3 Operation N8100BP, N8100-BRP & N8100NBP Operation 6. -F should be displayed indicating Fahrenheit. Use the down arrow to change it to -C for Celsius and hit The temperature control is used to turn the unit on and the stand-by button (lower left button) to enter the off as well as control the temperature of the cold pan.
  • Page 38: N8100-Fap Operation

    Operation Section 3 N8200P & N8200-STP Operation 8600P Hot/Cold Series Operation Hot Operation N8200P and N8200-STP series frost tops are designed to maintain an even layer of frost to pleasantly display DANGER product. Once turned on, the compressor will run continuously.
  • Page 39: 8600P Hot/Cold Series Operation

    Section 3 Operation N8700-D, N8700N, N8700-R & N8800 Series Cold Operation Operation Simply place the function switch to the COLD position. The compressor controller has been factory set and no These units are designed to hold warm food product temperature adjustment should be necessary. between 140ºF to 160ºF (60ºC to 71ºC).
  • Page 40 Operation Section 3 N8700-DESP Operation Wet Operation These units are designed to hold warm food product DANGER between 140ºF to 160ºF (60ºC to 71ºC). When operated at the highest temperature setting, the N8700-DESP series individually heated hot food units may top of the unit will become very hot.
  • Page 41: N8700-Desp Operation

    Section 3 Operation Wet Operation DANGER When operated at the highest temperature setting, the top of the unit will become very hot. Staff and customers using the equipment should be informed about this. DANGER Steam can cause serious burns. Always use some type of protective covering on your hands and arms when removing lids from the unit.
  • Page 42: Maintenance

    Section 4 Maintenance Cleaning and Sanitizing Procedures DANGER It is the responsibility of the equipment owner to Caution perform a personal protective equipment hazard assessment to ensure adequate protection during Maintenance and servicing work other than cleaning as maintenance procedures. described in this manual must be done by an authorized service personnel.
  • Page 43: Exterior Cleaning

    Section 4 Maintenance EXTERIOR CLEANING Defrosting Refrigerated cold pans MUST be defrosted daily. Never Warning use sharp objects or tools to clean or scrape ice/frost build When cleaning the unit, care should be taken to avoid up from the refrigerated cold pans. A puncture to the pan the front power switch and the rear power cord.
  • Page 44 DELFIELD 980 SOUTH ISABELLA ROAD, MOUNT PLEASANT, MI 48858 800-733-8821 WWW.DELFIELD.COM ©2019 Welbilt Inc. except where explicitly stated otherwise. All rights reserved. Part Number 9291458 Rev00 11/19...

Table of Contents