Page 1
Fresh Solutions, Fit For You Drop Ins 8100-EFP, N8000, N8000N, N8000-R, N8100BP, N8100-BRP, N8100-FAP, N8200P, N8200GP, N8200- STP, N8600P, N8700-D, N8700-DESP, N8700-R, N8800 Installation, Operation and Maintenance Manual Caution Read this instruction before operating this equipment. Original Document Part Number 9291458 Rev00 11/19...
Page 2
Safety Notices Warning This product contains chemicals known to the State Warning of California to cause cancer and/or birth defects or Read this manual thoroughly before operating, installing other reproductive harm. Operation, installation, and or performing maintenance on the equipment. Failure servicing of this product could expose you to airborne to follow instructions in this manual can cause property particles of glasswool or ceramic fibers, crystalline...
EXPORT MODELS • Verify warranty information, All export models are certified by: • View and download a copy of your warranty, • National Sanitation Foundation (NSF) at www.delfield.com/warranty • Technical Inspection Association • European Conformity Part Number: 9291458 REV00 11/19...
Warning If the LiquiTec unit cold pans leak, immediately call the Delfield service department directly at 1-800-733-8821 If a refrigerated base does not have a condensate not your local service agent.
Installation Section 2 Location Weight Of Equipment The location selected for the equipment must meet the Model Ship Weight 8100-EFP Series following criteria. If any of these criteria are not met, select 8118-EFP 169lbs (77kg) another location. 8132-EFP 215lbs (98kg) •...
Installation Section 2 Clearance Requirements Model Length Depth Height 12x20 Pans N8700-D-ESP-E Export Series DANGER N8717-D-ESP-E 17.89” 26” 9.5” Minimum clearance requirements are the same for (45cm) (66cm) (24cm)* noncombustible locations as for combustible locations. N8731-D-ESP-E 31.76” 26” 9.5” The flooring under the appliance must be made of a (81cm) (66cm) (24cm)*...
Dimensions Dimensions Model Counter Cutout Control Panel Cutout N8000N Series Dimensions Dimensions 45.75” x 17” N8046N 8100-EFP Series (116cm x 43cm) 8118-EFP 17” x 25” 66.50” x 17” N8068N (43cm x 64cm) (169cm x 43cm) 8132-EFP 30.75” x 25” N8000-R Series...
Page 14
Installation Section 2 Model Counter Cutout Control Panel Cutout Model Counter Cutout Control Panel Cutout Dimensions Dimensions Dimensions Dimensions N8100FAP Series N8200G-E Export Series N8131-FAP 30.25” x 25.5” N8231G-E 30.75” X 25” (77cm x 65cm) (78cm x 64cm) N8144-FAP 43” x 25.5” N8245G-E 44.63”...
Page 15
Section 2 Installation Model Counter Cutout Control Panel Cutout Model Counter Cutout Control Panel Cutout Dimensions Dimensions Dimensions Dimensions N8700DESP Series N8800-E Export Series N8717-DESP 16.87” X 25” 5” x 6.88” x 7.50” N8831-E 30.75” X 25” 12.25” x 4.25” x 7” (78cm x 64cm) (31cm x 11cm x 18cm) (43cm x 64cm)
Section 2 Installation Drop-In Counter Installation 1. Place the ice cooled drop-in unit through the counter cutout. ICE COOLED DROP-IN UNITS 2. A gasket is installed in the flange of each unit. N8000, N8000N, N8000-R The weight of the unit on the gasket forms a seal preventing liquids from seeping into the cut-out opening.
Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8100-EFNP, N8100BP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use.
Page 19
Section 2 Installation the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty. • Louver measures 13.00” x 25.00” (33cm x 64cm). • Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm) (typical installation).
Page 20
Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8100BRP, N8100-EFP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use.
Page 21
Section 2 Installation the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty. • Louver measures 13.00” x 25.00” (33cm x 64cm). • Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm) (typical installation).
Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8100-FAP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use.
Page 23
Section 2 Installation the 1” diameter drain on N8100-FAP models is shipped loose and must be connected during installation. Perforated Pan Clip Black Air ow Extrusions N8157-FAP, N8169-FAP and N8182-FAP have two 1” drains. A. Provided 1” (25mm) drain, nut and washer must Adapter Bars be field installed to an appropriate container or floor drain following local code requirements.
Installation Section 2 SELF-CONTAINED REFRIGERATED DROP-IN UNITS 8200P, N8200-GP, N8200-STP For any non-standard installation consult the factory. 1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. We recommend installing a remote located power switch for ease of use 2.
Page 25
Section 2 Installation C. Apply thin ring of plumbers putty around the drain. D. From the inside drop the drain into the drain hole. Use Screws to Secure Desired Depth 3 of 8 Screws Shown 6. Partitions must fully extend front to back and top to bottom.
Installation Section 2 SELF-CONTAINED COMBO HOT/COLD DROP-IN UNITS N8600P For any non-standard installation consult the factory. 1. Cabinet interior minimum dimensions: Dimension N8630P N8643P N8656P 29.75"/76cm 42.5"/108cm 55.25"/140cm 29"/74cm 29"/74cm 29"/74cm 28"/71cm 28"/71cm 28"/71cm 29.75"/76cm 42.5"/108cm 55.5"/140cm 25"/64cm 25"/64cm 25"/64cm 4.75”/12cm Min.
Page 27
Section 2 Installation NOTE: CONT: the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty. • Louver measures 20.00” x 25.00” (51cm x 64cm). • Louver Cutout Size is 18.50” x 22.50” (47cm x 57cm) (typical installation).
Installation Section 2 HOT FOOD WELL DROP-IN UNITS 1. Orient the control panel with the indicator light for each control to the right of the control. N8700-D, N8700-DESP, N8700N, N8700-R, N8800 • N8700 series units have 48” (122cm) of conduit. •...
Check all wiring connections, including factory terminals, before operation. Connections can become Model V, Hz, Ph Amps H.P. Plug loose during shipment and installation. 8100-EFP Series R290 8118-EFP 115, 60, 1 1/5 NEMA 5-15P 8132-EFP 115, 60, 1 1/5 NEMA 5-15P Warning...
Page 30
Installation Section 2 Model V, Hz, Ph Amps H.P. Plug Model V, Hz, Ph Amps H.P. Plug N8100NB-E Export Series N8700D-E Export Series N8146NB-E N8717-D-E 240, 50, 1 6.0 Amps / Hard Wire Varies Per 1.5 Amps / 230-240, 50, 1 N8168NB-E 1450 Watts 360 Watts...
Installation Section 2 Optional Auto Fill Installation • Option is a loose parts kit. Installation requires a plumber. APPLICABLE TO N8600 & N8800 MODELS 1. Locate mounting holes on outside operator drop-in body and mount float and bracket using thumb screws. 2.
Page 33
Section 2 Installation APPLICABLE TO N8700 MODELS 1. Locate mounting holes on outside operator drop-in body and mount float and bracket using thumb screws. 2. Install drain plumbing as shown. 3. Connect clear plastic tubing to 1/2” copper stub and connect to the float. Use hose clamps to secure. 4.
Section 3 Operation Product Quality in Cold Pans DANGER The on-site supervisor is responsible for ensuring that Warning operators are made aware of the inherent dangers of The operator of this equipment is solely responsible operating this equipment. for ensuring safe holding temperature levels for all food items.
8100-EFP units on and off. The unit must be turned off when not in use or overnight for defrosting and cleaning. 8100-EFP Series LiquiTec® Eutetic fluid cold pans are Operation / Indication adjusted at the factory to provide proper operation without...
Operation Section 3 Press upper or lower right button. CHANGING DISPLAY FROM FAHRENHEIT TO CELSIUS ON ERC112 CONTROL • Display show actual set-point (blinking). 1. Simultaneously hold the up and down arrows for • If buttons untouched for 3 seconds returns to 5 seconds to access menu for password protected normal.
Section 3 Operation N8100BP, N8100-BRP & N8100NBP Operation 6. -F should be displayed indicating Fahrenheit. Use the down arrow to change it to -C for Celsius and hit The temperature control is used to turn the unit on and the stand-by button (lower left button) to enter the off as well as control the temperature of the cold pan.
Operation Section 3 N8200P & N8200-STP Operation 8600P Hot/Cold Series Operation Hot Operation N8200P and N8200-STP series frost tops are designed to maintain an even layer of frost to pleasantly display DANGER product. Once turned on, the compressor will run continuously.
Section 3 Operation N8700-D, N8700N, N8700-R & N8800 Series Cold Operation Operation Simply place the function switch to the COLD position. The compressor controller has been factory set and no These units are designed to hold warm food product temperature adjustment should be necessary. between 140ºF to 160ºF (60ºC to 71ºC).
Page 40
Operation Section 3 N8700-DESP Operation Wet Operation These units are designed to hold warm food product DANGER between 140ºF to 160ºF (60ºC to 71ºC). When operated at the highest temperature setting, the N8700-DESP series individually heated hot food units may top of the unit will become very hot.
Section 3 Operation Wet Operation DANGER When operated at the highest temperature setting, the top of the unit will become very hot. Staff and customers using the equipment should be informed about this. DANGER Steam can cause serious burns. Always use some type of protective covering on your hands and arms when removing lids from the unit.
Section 4 Maintenance Cleaning and Sanitizing Procedures DANGER It is the responsibility of the equipment owner to Caution perform a personal protective equipment hazard assessment to ensure adequate protection during Maintenance and servicing work other than cleaning as maintenance procedures. described in this manual must be done by an authorized service personnel.
Section 4 Maintenance EXTERIOR CLEANING Defrosting Refrigerated cold pans MUST be defrosted daily. Never Warning use sharp objects or tools to clean or scrape ice/frost build When cleaning the unit, care should be taken to avoid up from the refrigerated cold pans. A puncture to the pan the front power switch and the rear power cord.