Operation
N8200P & N8200-STP Operation
N8200P and N8200-STP series frost tops are designed
to maintain an even layer of frost to pleasantly display
product. Once turned on, the compressor will run
continuously. There is no temperature control. The ON/OFF
switch is the only means available to cycle the unit.
Since it takes time for the frost to accumulate initially, the
unit should be turned on approximately one hour before it
is required. Product should not be placed on the frost top
prior to turning the unit on, because it may freeze to the
surface of the unit.
The unit must be turned off when not in use or overnight
for defrosting and cleaning.

Operation N8200GP

N8200GP Series granite cold slabs are designed to maintain
a low temperature surface for quick turn products such
as ice cream. Frost patterns will vary depending on room
conditions such as temperature, humidity and airflow. The
work zone of the granite surface is considered to be inside a
2.0" (5.1cm) perimeter. Temperatures in the perimeter zone
may be higher and again the frost patterns in this area will
vary based on room conditions.
Unit is controlled by an on/off switch. Once turned on, the
unit will run continuously. There is no temperature control
in this unit. Turn the unit on approximately two hours prior
to use to allow for ample cool down time. At 75˚F ambient
temperature the unit will reach operating temperature of
0˚F to 20˚F in 2 hours.
The unit must be turned off when not in use or overnight
for defrosting and cleaning.
38
8600P Hot/Cold Series Operation
Hot Operation
When operated at the highest temperature setting, the
top of the unit will become very hot. Staff and customers
using the equipment should be informed about this.
,
Never use anything other than plain water in the wells
or tank. Failure to observe this warning may result in
personal injury or damage to the unit.
,
Using ice in a hot food well can cause condensation and
damage to the well over time.
Drain the water from units daily for unit longevity.
N8600P Series hot and cold combination pans must be
operated with water in the well for proper hot operation.
Fill well with a minimum of 4.0" (10.2cm) of water. Place
function switch in HOT position to begin heating. Turn
thermostat dial to the desired temperature.
To turn unit off, simply move the function switch to OFF
position. Drain water and allow unit to cool before cleaning
or switching to cold operation.
Switching From Hot To Cold Operation
1. Place the function switch in the OFF position and drain
out hot water.
2. Allow the unit to cool until it can be safely cleaned.
3. When clean up procedures are complete, unit will be
ready for cold operation. This takes about one hour.
,
To assure maximum compressor life, do not switch
from "hot" to "cold" operation without allowing a cool
down period. Never switch from hot to cold operation
while hot water remains in the pans. Failure to observe
this warning will greatly reduce compressor life and
eventually cause premature compressor failure.
n
Opening the drain cock will lead to the outflow of the
hot contents of the bains-marie.