SELF-CONTAINED COMBO HOT/COLD DROP-IN UNITS
N8600P
For any non-standard installation consult the factory.
1. Cabinet interior minimum dimensions:
Dimension
N8630P
A
29.75"/76cm
B
29"/74cm
C
28"/71cm
D
29.75"/76cm
E
25"/64cm
F
4.75"/12cm
Dimension
N8669P
A
68"/173cm
B
29"/74cm
C
28"/71cm
D
68"/173cm
E
25"/64cm
F
4.75"/12cm
2. Place the condensing unit through the counter cutout.
3. Extend the telescoping duct from the front of the
condensing unit to the back of the louver. This will
prevent recirculation of discharge air. Export models do
not have a telescoping duct, skip to step 6.
4. Put eight provided screws through the telescoping
duct side walls to hold it at the desired depth.
26
N8643P
N8656P
42.5"/108cm
55.25"/140cm
29"/74cm
29"/74cm
28"/71cm
28"/71cm
42.5"/108cm
55.5"/140cm
25"/64cm
25"/64cm
Min. 2.75"/7cm -
Max. 4.75"/12cm
N8681P
N86120P
80.75"/205cm
101.75"/258cm
29"/74cm
29"/74cm
28"/71cm
28"/71cm
80.75"/205cm
101.75"/258cm
25"/64cm
25"/64cm
Min. 2.75"/7cm -
Max. 4.75"/12cm
D
B
A
18.50"
(47cm)
22.50"
(57cm)
Use Screws to Secure Desired Depth
3 of 8 Screws Shown
5. Partitions must fully extend front to back and top to
bottom.
6. Louver cutout must extend to bottom of cabinet and
align with condenser face.
NOTE: The louver provided must be installed in front of
Part Number: 9291458 REV00 12/19
Section 2
F
E
C
4.25"
12.25"
(11cm)
(31cm)