Delfield F2000 Series Service, Installation And Care Manual
Delfield F2000 Series Service, Installation And Care Manual

Delfield F2000 Series Service, Installation And Care Manual

Equipment stands

Advertisement

Quick Links

F2000 and F17 Series Equipment Stands
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of
damage! Inspect all components immediately. See page 2.
To assure proper operation a 2" airspace must be maintained between the lowest part of any cooking equip-
ment and the top of this unit. Cooking equipment must have a barrier (i.e. bottom, drip pan) between its heat
source and the top of the equipment stand. Failure to comply with this could severely damage the equipment
stand and void all warranties.
Warning
Delfield
July 2012
®

Advertisement

Table of Contents
loading

Summary of Contents for Delfield F2000 Series

  • Page 1 Delfield ™ ® F2000 and F17 Series Equipment Stands Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. Warning To assure proper operation a 2" airspace must be maintained between the lowest part of any cooking equip- ment and the top of this unit.
  • Page 2 Operate equipment only on the type of electricity indicated on the specification plate. • Unplug the unit before making any repairs. • Retain this manual for future reference. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 3: Table Of Contents

    Maximum Cooking Equipment Weight Capacity ....8 Maintenance ..............9-10 ©2012 The Delfield Company. All rights reserved. Reproduction without written permis- sion is prohibited. “Delfield” is a registered trademark of The Delfield Company. Refrigerator Wiring Diagrams ..........11 Freezer Wiring Diagrams ............12 Regulatory Certifications Replacement Parts by Model ........
  • Page 4: F2000 Specifications

    10.0 5-15P 672lbs/305kg 2341 144/16º/21º F2999C (6) 27" 115/60/1 10.0 5-15P 691lbs/313kg 1029 2341 144/16º/21º F29110C (6) 32" 115/60/1 12.0 5-15P 766lbs/347kg 1143 2630 144/18º/19º Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 5: F17 Specifications

    (2) 19” (2) 27” 115/60/1 10.0 400lbs/181kg 1461 160/9º/-12º F17FR66 (4) 27” 115/60/1 10.0 475lbs/215kg 1647 160/10º/-13º F17FR76 (4) 32” 115/60/1 10.0 560lbs/254kg 1879 160/12º/-15º Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 6: Installation

    It is the owner’s and operator’s responsibility to provide a con tain er or outlet for drainage. CAUTION Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 7: Operation

    Evap Fan Evap Fan Evap Fan Evap Fan Freezer Defrost Self-contained models use hot gas to defrost the evaporator coils. Remote freezers use electric defrost. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 8: Temperature Control Settings

    1800lbs/ 816kg 766lbs/ 347kg 450lbs/ 204kg 584lbs/ 265kg F2660C 1500lbs/ 680kg 418lbs/ 190kg 150lbs/ 68kg 932lbs/ 423kg F2694C 1500lbs/ 680kg 500lbs/ 227kg 300lbs/ 136kg 700lbs/ 318kg Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 9: Maintenance

    Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 10 Over shelves and other items mounted to the top of the counters should never be installed in the field due to the potential damage to the refrigeration system. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 11: Refrigerator Wiring Diagrams

    Wiring Diagram: F2800 & F17 Series Remote Refrigerators 115V/60HZ/1PH Note: Wiring for F2800 series includes junction box with 6" leads for field connection and wiring to evaporator fans and coils only. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 12: Freezer Wiring Diagrams

    Wiring Diagram: F2700 & F17 Series Remote Freezers Note: Wiring for F2700 series includes junction box with 6' leads for field connection and wiring to evaporator fans and coils only. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 13: Replacement Parts By Model

    3516135 Thermometer, Hanging, 4” 2194791 Thermometer Cable, Danfoss 2194792 Thermometer Display, Digital, Danfoss 000-282-006T Thermostat Assembly, Danfoss * Assembly and part prints on pages 17-21. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 14 F17DD - All Models Part # Description *000-405-0031 Bracket, cutting board, left hand *000-405-0035 Bracket, cutting board, right hand * Assembly and part prints on pages 17-21. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 15 Clip, Coil Air Baffle, Right *000-248-0037 Coil Assembly, R404A, Ref, Fan Lt *000-248-0030 Coil Assembly, R404A, Ref * Assembly and part prints on pages 17-21. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 16 Assembly, drawer, 19” freezer, lo-profile *000-AEW-003B Assembly, drawer, 27” freezer, lo-profile *000-AEW-003A Assembly, drawer, 32” freezer, lo-profile * Assembly and part prints on pages 17-21. Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 17 3516322 Filter drier 3516446 Compressor, Relay, Danfoss 3516456 Coil, condenser, 3/4hp 3516322 Drier, Filter, (2)Inlet 039-231-0030 Pan, Condensate, SM 3516454 Coil, Condenser, 1/5, 1/4, 1/3HP Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 18: Condensing Unit Assemblies

    Fan Guard 3527000 Compress, Danfoss, NF7CLS 2194788 Start Capacitor 3516322 Filter Drier 075-231-0030 Pan, Condensate 2162717 Fan Motor 3516454 Condenser Coil 3516438 Relay, overload, compressor Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 19: Evaporator Coil Assemblies

    Probe, Defrost, Danfoss, Control 2194046 Control, Limit, Fan Delay/Defrost 2194809 Probe, Temp, Sensor, Danfoss 2194631 Fuse, Defrost Heater, 7 Amp 2184323 Harness, coil, frz, male, remote Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 20: Drawer Assemblies

    Assembly, Drawer Box, 32” 3234925 Interm profile, LH (with nylon rollers) 3234925 Interm Profile, LH, Reg 3234926 Interm profile, RH (with nylon rollers) 3234926 Interm Profile, RH, Reg Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 21: Replacement Part Prints

    000-298-003V Control Assembly, Frz, 5-15 2194758-4 Control, Freezer, 115V 2194758-4 Control, Freezer, 115V 3516247 Control, Pressure, High 2190154 Rocker switch, 20A/125V 2190154 Rocker switch, 20A/125V Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 22: Standard Labor Guidelines

    F2000/F17 Series Equipment Stand Service and Installation Manual Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock.
  • Page 23: Warranties

    During this one year warranty period, Delfield will repair Delfield shall not be liable in any manner for any default or delay in or replace any defective part or portion there of returned to Delfield by performance hereunder caused by or resulting from any contingency the Original Purchaser which Delfield determines was defective due to beyond Delfield’s control, including, but not limited to, war,...
  • Page 24 Serial# Installation Date General Conditions Delfield shall not be liable in any manner for any default or delay in performance thereunder caused by or resulting from any contingency beyond Delfield’s control including, but not limited to, war, In addition to the Standard One Year Warranty on the Motor-...
  • Page 25 The sole and exclusive remedies judgment, affect its quality or efficiency. This Warranty does not of any person relating to the Unit, and the full liability of Delfield for apply to any Unit that has been moved from the location where it any breach of this Warranty, will be as provided in this Warranty.
  • Page 26: Notes

    F2000/F17 Series Equipment Stand Service and Installation Manual Notes Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 27 F2000/F17 Series Equipment Stand Service and Installation Manual Notes Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 28 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (989) 773-7981 or (800) 733-8829 • Fax (989) 773-3210 • www.delfield.com Delfield reserves the right to make changes in design or specifications without prior notice. ©2012 The Delfield Company. All rights reserved. Printed in the U.S.A.

Table of Contents