Delfield N8100-FA Service, Installation And Care Manual

Delfield N8100-FA Service, Installation And Care Manual

Drop ins hot food wells, cold pans, frost tops and hot/cold food wells
Hide thumbs Also See for N8100-FA:

Advertisement

N8000, N8100B, N8100-FA, 8100-EF, N8200,
N8200G, N8600, N8700-D, N8800 Drop Ins
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of
damage! Inspect all components immediately. See page 2.
Hot Food Wells, Cold Pans, Frost tops and
Hot/Cold Food Wells
Effective Date August 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N8100-FA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Delfield N8100-FA

  • Page 1 N8000, N8100B, N8100-FA, 8100-EF, N8200, N8200G, N8600, N8700-D, N8800 Drop Ins Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. Hot Food Wells, Cold Pans, Frost tops and Hot/Cold Food Wells Effective Date August 2006...
  • Page 2: Table Of Contents

    Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment. For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com Serial Number Location The serial number on self-contained refrigerated units is on the electrical specifications tag located near the condensing unit.
  • Page 3: Receiving And Inspecting Unit

    HERTZ/PHASE H.P. AMPS 115/60/1 17” X 45.75” (43.2cm x 113.7cm) 17” x 66.5” 115/60/1 (43.2cm x 168.9cm) For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com # OF 12” X 20” SHIPPING PANS HELD WEIGHT 37 lbs (17 kg)
  • Page 4 N8656 56.25” (142.9cm) 26”(66cm) 23.75” (60.3cm) 55.25” x 25” (140.3cm x 63.5cm) N8669 69” (175.3cm) 26”(66cm) 23.75” (60.3cm) N8681 81.75” (207.6cm) 26”(66cm) 23.75” (60.3cm) 80.75” x 25” (205.1cm x 63.5cm) For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com LOUVER CUTOUT VOLTZ/HERTZ DIMENSIONS PHASE...
  • Page 5 VOLTZ/HERTZ DIMENSIONS PHASE ” x 11” 115/60/1 ” x 11” 115/60/1 ” x 11” 115/60/1 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com # OF VOLTS/HERTZ/ WELLS PHASE AMPS 120/60/1 120/60/1 16.7 208-230/60/1 14.4/15.9 150 lbs (68 kg) 208-230/60/1 19.2/21.3 170 lbs (77 kg)
  • Page 6: N8000, N8000N, N8100B, N8100Nb, N800, N800G, 8100-Fa, 8100-Ef Series

    Self-contained refrigerated units (N8100, N800 and N800G Series) require airflow to the compressor. A 13” x 5” louver is (33 cm x63.5 cm) provided by Delfield and must be installed in the counter in front of the condenser. See specifications on page 3 for louver cutout dimensions.
  • Page 7: N8600 Series

    A 13” x 5” louver is (33.0 cm x 63.5 cm) is provided by Delfield and must be installed in the counter in front of the condenser. See page 3 & 4 for louver cut-out dimensions. The rear must have an opening to permit removal of heated air.
  • Page 8: N8100-Fa

    COLDER near the knob, with an arrow to indicate the adjustment direction. These controls are field adjustable and do not require a ser- vice agent. If you have any questions, feel fre to contact the Delfield Service Department. In attempting to adjust the pressure control, you can do damage to the unit by accidentally adjusting the differential.
  • Page 9: N8700D, N8700N, & N8800 Series

    When operated dry, the well bottoms become very hot. Do not allow unprotected skin to contact any well surface. NG E For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com 17 differential 25 cut-in, 8 cut-out...
  • Page 10: N8600

    Common items include, tomatoes, peppers and CAUTION other vegetables. For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com To assure maximum compressor life, do not switch from “hot” to “cold” operation without allowing a cool down period. Never switch from hot to cold operation while hot water remains in the pans.
  • Page 11: Unit Assembly N8100-Fa

    WITH AIR DEFLECTOR WIRING DIAGRAM 115V N8100FA N8000 Series Drop-In Installation and Operation Manual BLACK AIRFLOW EXTRUSIONS PERFORATED PAN CLIP ADAPTER BARS COIL ASSY COVER For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com PLEXIGLAS END CAPS...
  • Page 12 Wiring Diagram - N8100B, N8100NB, N8200 & N8200G N8100B Series-115V N8200 & N8200G Series- 115V ON/OFF SWITCH Wiring Diagram - N8800 - 208/230V THERMOSTAT For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com COOLING T'STAT CONDENSER FAN COMPRESSOR 115V CONDENSER FAN...
  • Page 13: Single Phase

    15.9 14.4/15.9 19.2 21.3 19.2/21.3 26.6 24/26.1 28.8 31.3 28.8/31.3 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com 1000 W - 120V OR 1000/1222 W - 208-230 V HEATING ELEMENT 14.4/15.9 14.4/15.9 19.2/21.3 14.4/15.9 19.2/21.3 19.2/21.3 28.8/31.3...
  • Page 14: N8600

    ONE OR TWO HEATERS REMOTE REFRIGERATION SYSTEM FUNCTION SWITCH COLD COOLING T' STAT HEATING T' STAT For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com L1 G CONDENSER FAN COMPRESSOR 120V HEATER 1 HEATER 2 PILOT LIGHT...
  • Page 15: N8600

    N8000 Series Drop-In Installation and Operation Manual L1 G COOLING T' STAT HEATING T' STAT L1 G HEATING T' STAT For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com CONDENSER FAN COMPRESSOR 120V HEATER 1 HEATER 2...
  • Page 16: On/Off Switch

    N8000 Series Drop-In Installation and Operation Manual WIRING DIAGRAM - 8100-EF, 8100-EFN ON/OFF SWITCH For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 17: Cutout Dimension

    43-ALS-003 N8130B 43-ABO-0001 N8143B N8156B N8168NB N8169B N8181B For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com 5” Cap Tube Size/Length .036 x 7” .036 x 7” .036 x 7” .04 x 10” .04 x 10” .04 x 10”...
  • Page 18: N8100-Fa Replacement Parts List

    FAN COVER FAN BLADE FAN MOTOR FAN BRACKET PLEXIGLAS END CAP S/S THUMB SCREW Cond. Unit Timer Pressure Control For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com N8131-FA N8144-FA N8157-FA 2-PAN 3-PAN 4-PAN 6-0V3-0030 6-0V3-0031 6-0V3-003...
  • Page 19 000-AWP-0000 036035 3516101 190010 183348 194099 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com Description condensing unit, 1/3 h.p., low, R-404a, NB switch, assembly, with bracket, 800 heat exchanger assembly, condensing unit dryer, filter, .5” dia.in/out...
  • Page 20 N8000 Series Drop-In Installation and Operation Manual Narrow Base Condensing Unit Assembly - N8100B & N8100NB 1/5 h.p. For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com 1/5 HORSE POWER R-134a, Low Used on N8118B, N8130B, N8143B, N8146NB, N8168NB...
  • Page 21 183300 3516067 3516047 194013 06-ANM-0033 08-ANK-0030 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com Description compressor, 1/4 h.p.,115v/60hz guard, wire, fan, condenser unit, N8100 harness, wire, power cord, N8100 coil, condenser, 9 x 10, R-134a, N8100 thermostat fan assembly, condenser, 8”...
  • Page 22 Used on 8100-EF & 8100-EFN 3526716 Condensing Unit 1/4 115/60 R404A 3516101 Dryer, Filter, 1/4 ODF Low 2194231 Thermostat 2194099 On/off switch For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com Filter Dryer Relay Compressor Receiving Tank Capacitor...
  • Page 23 KNOB, THERMOSTAT CONTROL 99134 LABEL, “HOT/OFF/COLD” 3516047 TEMPERATURE CONTROL 194185 CONTACTOR RELAY 30 AMP 10V 19494 IMMERSION HEATER 40V 1PH 5KW N8000 Series Drop-In Installation and Operation Manual For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 24 N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Infinite Control - N8700 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com For models N8700D, N8700N Delfield Part # Description 194110 control, infinite, 40v, 14a...
  • Page 25 Delfield Part # 193984 334357 194007 194006 334556 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com Description thermostat 30A for M# N8873 and N8887 plate, deflector, DFW, with drain element, heating, 08/30v, 1000/1w element, heating, 10v, 1000w...
  • Page 26: Standard One Year Warranty

    Unit or any exhaust system. Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war,...
  • Page 27: Additional Four Year Protection Plan

    General Conditions Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war,...
  • Page 28: Installation Date

    (800) 733-889. Model: ____________________ S/N: ___________________ Installation Date: ____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com. DM8000 08/06...

This manual is also suitable for:

8100-efN8000N8100bN8200N8200gN8600 ... Show all

Table of Contents