Installation
SELF-CONTAINED REFRIGERATED DROP-IN UNITS
8100BRP, N8100-EFP
For any non-standard installation consult the factory.
1. Install a GFCI receptacle a minimum of 14" (36cm) up
from the cabinet bottom inside the partitions. We
recommend installing a remote located power switch
for ease of use.
2. Cabinet interior minimum dimensions:
Dimension
N8146BRP
A
45.75"/116cm
B
19"/48cm
C
26"/66cm
D
45.75/116cm
E
17"/43cm
F
Min. 2.75"/7cm - Max. 4.75"/12cm
Dimension
N8118-EFP
A
22.38"/57cm
B
27.75"/70cm
C
26"/66cm
D
17"/43cm
E
25"/64cm
F
Min. 2.75"/7cm - Max. 4.75"/12cm
Dimension
N8159-EFP
A
57.87"/147cm
B
27.75"/70cm
C
26"/66cm
D
57.87"/147cm
E
25"/64cm
F
Min. 2.75"/7cm - Max. 4.75"/12cm
3. Place the condensing unit through the counter cutout.
4. Extend the telescoping duct from the front of the
condensing unit to the back of the louver. This will
prevent recirculation of discharge air. Export models do
not have a telescoping duct, skip to step 6.
5. Put eight provided screws through the telescoping
duct side walls to hold it at the desired depth.
20
N8168BRP
66.5"/169cm
19"/48cm
26"/66cm
66.5"/169cm
17"/43cm
N8132-EFP
N8145-EFP
30.75"/78cm
44.25"/112cm
27.75"/70cm
27.75"/70cm
26"/66cm
26"/66cm
30.75"/78cm
44.25"/112cm
25"/64cm
25"/64cm
N8172-EFP
N8186_EFP
71.5"/182cm
85"/216cm
27.75"/70cm
27.75"/70cm
26"/66cm
26"/66cm
71.5"/182cm
85"/216cm
25"/64cm
25"/64cm
D
B
A
11.50"
(29cm)
22.50"
(57cm)
Use Screws to Secure Desired Depth
3 of 8 Screws Shown
6. Partitions must fully extend front to back and top to
bottom.
7. Louver cutout must extend to bottom of cabinet and
align with condenser face.
NOTE: The louver provided must be installed in front of
Part Number: 9291458 REV00 12/19
Section 2
E
F
C