the condensing unit's finned coil. Any restriction to the
proper air flow will void the compressor warranty.
Louver measures 13.00" x 25.00" (33cm x 64cm).
Louver Cutout Size is 11.50" x 22.50" (29cm x 57cm)
(typical installation).
Typical Counter Cabinet
8. The 1" diameter drain on N8100BP, N8100-EFNP
and N8100P models is shipped loose and must be
connected during installation.
A. Provided 1" (25mm) drain, nut and washer must
be field installed to an appropriate container or
floor drain following local code requirements.
Sinks come standard with 1-1/2" basket strainer
assemblies.
B.
Remove/drill foam out of drain hole.
C. Apply thin ring of plumbers putty around the
drain.
D. From the inside drop the drain into the drain hole.
E.
From the outside secure the drain with the washer
and nut.
Part Number: 9291458 REV00 12/19
Duct
Partitions Not Shown
F.
Tighten the nut with channel locks, use a fork to
hold the drain in place if necessary.
G. Clean up excess plumbers putty.
Suggested Drainage Trap
Units may increase in performance if they have a
drainage trap or shut-off valve installed. Installing the
trap will stop warm air being introduced into the dry
well of the unit.