1-2 REAR PANEL

A) Optional ...............................• WGA-670B-0:
B) Terminal Board ....................Nos.1 to 5:
C) Fitting Metal ........................• Fitting metal for fixing the WGA-670B to the panel.
A
C
• WGA-670B-1:
• WGA-670B-7:
1: Shield, 2: Bridge output (+), 3: Bridge exciter (-),
4: Bridge output (-),
Nos. 6 to 9:
6: COM, 7: RESET, 8: HOLD, 9: Digital ZERO input
Nos. 12 to 14:
12: Current output, 13: Common, 14: Voltage output
Nos. 15 to 17:
15: COM, 16: LOW limit output, 17: HIGH limit output
No. 18:
Nos. 19 & 20:
Nos. 10 & 11:
Nos. 21 & 22:
21: TEDS(+), 22: TEDS(COM)
None
Interface to output BCD coded WGA-670B indication.
Interface to connect the TEDS signal of the WGA-670B.
Also equipped with RS-232C interface.
Item A) in the above figure shows the WGA-670B-7.
Transducer connection terminals.
5: Bridge exciter (+)
Control contact input terminals.
Analog output terminals.
Comparator open collector output terminals
Protective ground terminal
Grounding should be made to prevent an electric shock
hazard.
LINE IN. Connect AC power supply.
Spare terminals. No connection
TEDS signal connection terminals.