5 Versions

5.1 Caméra Day/Night
MAXIMUS MPX SERIES2 - CHOIX DES CONFIGURATIONS
Tension
MPXHD
1
230Vac
2
24Vac
3
120Vac
Tab. 2
MAXIMUS MPX SERIES2 - CERTIFICATIONS ET MARQUAGES
Références
Certification
MPXHD**A0**C
ATEX
IECEX
UL Hazardous Location
America
UL Hazardous Location
Canada
MPXHD**D0**C
ATEX
IECEX
Tab. 3
14
Caméra
1
Caméra Videotec super low-
light FullHD Jour/Nuit 30X zoom
Marquage
II 2 G Ex db IIC T6...T5 Gb
II 2D Ex tb IIIC T85°C...T100°C Db
Ex db IIC T6...T5 Gb
Ex tb IIIC T85°C...T100°C Db
Class I, Zone 1, AEx db IIC T6...T5 Gb
Zone 21, AEx tb IIIC T85°C...T100°C Db
Class I, Div 2, Group A, B, C, D T6...T5
Class II, Div 2, Group F, G T6...T5
Ex db IIC T6...T5 Gb X
Ex tb IIIC T85°C...T100°C Db X
Class I, Div 2, Group A, B, C, D T6...T5
Class II, Div 2, Group F, G T6...T5
II 2G Ex db IIC T4 Gb
II 2D Ex tb IIIC T135°C Db
Ex db IIC T4 Gb
Ex tb IIIC T135°C Db
Classe de température et
température ambiante
A T6...T5 -40°C/+60°C or +70°C
D T4 -40°C/+80°C
Température ambiante
-40°C ≤ Ta ≤ +60°C or +70°C
-40°C ≤ Ta ≤ +60°C or +70°C
-40°C ≤ Ta ≤ +80°C
0
0
0
C
Température
d'entrée des
câbles
80°C
80°C avec Ta = 69°C
81°C avec Ta = 70°C
90°C