8.2.5

Replacing a fan in the Adapter Module 600

Preparatory steps
● Disconnect the drive line-up from the power supply
● Allow unimpeded access to the Adapter Module 600 (AM600).
● Check that the device is in a no-voltage condition
Replacing a fan in the AM600
Figure 8-4
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3
DANGER
Danger to life due to electric shock when replacing a fan
Because of the DC link capacitors, a hazardous voltage is present for up to five minutes
after the power supply has been switched off.
Contact with live parts can result in death or serious injury.
• Switch the power supply off before replacing the fan.
• Wait at least 5 minutes after switching off.
• Before starting any work, also check that the system is in a voltage-free state by
measuring at the DC link terminals DCP and DCN.
• Only use the following fan module with fans:
– Siemens article number: Fan module AM600 6SL3566-0AA00-0AA0
Fixing screws
Fan cover
Fan connector
Replacing a fan in the AM600
Service and maintenance
8.2 Replacing components
153