Cabinet design and EMC S120M
7.3 Connection system
Hybrid Cable
The Hybrid Cable (prefabricated hybrid cable) comprising DRIVE-CLiQ signal cable and
signal/power cables.
Table 7- 4
Technical data
Maximum permissible number of insertion cycles
Bending radii
Tensile strength
Properties in the cable carrier
depending on the traversing path (see the diagram below)
1)
Figure 7-4
124
Technical data of the Hybrid Cable 6FX8002-7HYxx-xxxx
Single bends
Multiple bends
Static
Dynamic
Minimum bending radius
Maximum permissible acceleration
Maximum traversing speed
Bending cycles
Permissible horizontal traversing path
Angle of torsion
Hybrid Cable: acceleration as a function of the traversing path (minimum curve)
Unit
mm
mm
N/mm
N/mm
mm
m/s
1)
m/min
m
Grd
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3
Value
50
≥60
≥112.5
50
2
20
2
105
50
2
300
5 000 000
50
±30