Hybrid Connector - Siemens SINAMICS S120M Manual

Distributed drive technology
Hide thumbs Also See for SINAMICS S120M:
Table of Contents

Advertisement

The DRIVE-CLiQ signals of the incoming hybrid line are terminated and the DRIVE-CLiQ
signals of the DRIVE-CLiQ cable are fed into the new hybrid line. All other connections are
only looped through from the inputs to the outputs.
Figure 5-1
Note
The X1 (input) and X2 (output) connections must not be interchanged.
5.3.2

Hybrid connector

Connecting the Hybrid Cable from the S120M of the previous line
Table 5- 1
Terminal strip X1 (IN)
Terminal
1
2
3
4
5
6
7
8
9
-
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3
Block diagram of DRIVE-CLiQ Extension
Signal name
1 (TXP)
2 (RXP)
3 (TXN)
4 (RXN)
PE
M
+
DCN
DCP
DQ_SHIELD
Technical data
Transmit data +
Receive data +
Transmit data -
Receive data -
Potential equalization
Electronics ground
48 VDC power supply
DC link voltage - (M600)
DC link voltage + (P600)
Shield
DRIVE-CLiQ Extension
5.3 Interface description
103

Advertisement

Table of Contents
loading

Table of Contents