Note
Radio service interference due to radio disturbances in residential environments
In a residential environment this product can cause radio disturbances, which may make
interference suppression measures necessary.
This device is not designed for unrestricted operation in the first environment (residential
environment) and may not be used in the first environment without suitable interference
suppression measures.
• Have qualified personnel carry out the installation and commissioning with suitable
interference suppression measures.
2.6

Derating as a function of the installation altitude

Direct connection to line circuits up to 3-ph. 480 VAC is only allowed at altitudes between
2,000 m and 4,000 m if the neutral point of the line supply is grounded (TN or TT line
supply). Otherwise, a suitable isolation transformer must be connected upstream. The
secondary system of the isolation transformer can be grounded or insulated.
2.7

Recycling and disposal

The applicable national guidelines must be observed when disposing of the product.
The products described in this manual are extensively recyclable on account of the low-toxic
composition of the materials used. For environmentally-compliant recycling and disposal of
your electronic waste, please contact a company for the disposal of electronic waste.
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3
2.6 Derating as a function of the installation altitude
System overview
45