System overview
2.4 SINAMICS S120 components
Cable assemblies intended to be used for signal connectors X3/X4 shall comply with the
requirements in the Standard for Cable Assemblies and Fittings for Industrial Control and
Signal Distribution UL2238 (UL Category CYJV/CYJV2).
Table 2- 4
Technical data of the DRIVE-CLiQ Extension (DQE) according to UL
DQE
Max. ambient temperature
Electronics power supply (X1/X2)
Input / Output Voltage
Input / Output Current
DC-Bus Supply (X1/X2)
Input / Output Voltage
Input / Output Current
Enclosure type
Table 2- 5
Technical data of the Hybrid Cabinet Bushing (HCB) according to UL
HCB
Max. ambient temperature
Line Electronics / Control Power (output)
Input / Output Voltage
Input / Output Current
DC-Bus Supply
Input / Output Voltage
Input / Output Current
Enclosure type
Table 2- 6
Technical data of the Hybrid Cable according to UL
Hybrid Cable
Max. cable temperature
Electronics power supply
Voltage
Current
Core cross-section
DC link supply/grounding
Voltage
Current
Core cross-section
Signal cores
Voltage
Current
Core cross-section
To connect the distributed components HCB, DQE and S120M with one another and to the
AM 600, it is only permissible to use the 6FX8002-7HY..-.... Hybrid Cable.
34
Unit
6SL3555-0AA00-6AB.
°C
40
V
48
DC
A
10
DC
V
510 ... 700
DC
A
20
DC
Type 1
Unit
6SL3555-2DA00-0AA.
°C
40
V
48
DC
A
10
DC
V
510 ... 700
DC
A
20
DC
Type 1 (exterior)
Unit
6FX8002-7HY..-....
°C
80
V
48
DC
A
10
DC
mm
2.5
2
V
720
DC
A
20
DC
mm
4
2
V
30
DC
A
1
DC
AWG
22
55 (with derating)
48
10
510 ... 700
12
55 (with derating)
48
10
510 ... 700
12
SINAMICS S120M Distributed Drive Technology