Siemens SINAMICS S120M Manual page 97

Distributed drive technology
Hide thumbs Also See for SINAMICS S120M:
Table of Contents

Advertisement

Derating characteristics
For SINAMICS, the rated data is only applicable for a specified range. Outside this range,
certain performance data are restricted. For SINAMICS systems there are constraints
regarding the ambient temperature, pulse frequency and installation altitude, for example.
The following derating characteristics apply for the S120M:
Derating characteristics as a function of the ambient temperature
Figure 4-27
The full torque is output in the range between -15 ℃ and +40 ℃.
For temperatures between +40 °C and +55 °C, the static torque must be reduced according
to the diagram above. Derating must be moved on the basis of the static torque in the form
of a parallel movement of the torque characteristic (see the schematic diagram below).
Figure 4-28
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3
Derating as a function of the ambient temperature
Schematic diagram for torque rating as a function of the ambient temperature
S120M
4.9 Technical data
97