Cable layout and interconnections

Installing the EC150-3C cables

Topics
Connecting the transducer cable to the Power Supply Unit, page 87
Schematics, page 94

Connecting the transducer cable to the Power Supply Unit

The purpose of the Power Supply Unit is to provide the EC150-3C with the necessary
power for operation. Correct wiring is crucial for the operational performance of
the EC150-3C. Electrical connections can only be made by skilled personnel (ship
electricians, technicians or engineers).
Prerequisites
You must be equipped with a standard set of tools. This tool set must comprise the
normal tools for cable installation tasks. This includes different screwdriver types,
pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in
various sizes. We recommend that all tools are demagnetized to protect your equipment.
Depending on the tasks at hand, additional tools may be required.
The following special tool is required for this task:
• Hot air gun
Note
All electronic installations and corresponding wiring must be in accordance with the
vessel's national registry and corresponding maritime authority and/or classification
society. Only skilled and authorized personnel can install the EC150-3C cables.
Kongsberg Maritime will not accept any responsibility for errors, malfunctions or
damage to system or personnel caused by improper wiring.
Context
The Power Supply Unit must be installed at an appropriate distance from the transducer.
The transducer cable enters the Power Supply Unit through the cable gland at the bottom
of the cabinet. The transducer cable is 40 metres long. The cable can not be extended.
87
438371/A