Summary of Contents for Simrad ES120-7CD - INSTALLATION REV A
Page 1
Installation manual Simrad ES120-7CD 120 kHz split-beam deep water transducer www.simrad.com T E C H N O L O G Y F O R S U S T A I N A B L E F I S H E R I E S...
Page 3
Simrad ES120-7CD Installation manual This document provides a general description of how to install the Simrad ES120-7CD Split-beam transducer. The information must be regarded as general guidelines and recommendations only. The installation shipyard must design and manufacture installation hardware to fit the ES120-7CD transducer on each individual towed body.
Whenever required, the installation shipyard must also have the installation approved by the applicable maritime authorities. Additional information For additional detailed information about the transducer to be installed, refer to the documentation provided with the transducer. Drawings and descriptions can also be obtained from http://www.simrad.com. 339149/A...
ES120-7CD transducer are located in the Drawing file on page 18. Technical specifications Refer to the ES120-7CD product specification. Additional parts provided for installation The following items can be supplied by Simrad to facilitate installation: • Mounting ring: ES1–204719 • Clamping ring: ES1–203672...
TOWED BODY DESIGN A towed body used to hold the transducer is not provided by Simrad. The design and manufacturing of such a body must be made by your own organisation, or by a third party you wish to engage to do this. During the design phase, the following considerations must be made.
Page 10
Simrad ES120-7CD the sound energy, and may in worst cases block the sound transmission totally. Therefore, design the towed body so that it can operate in deep water. Caution Observe the maximum operational depth of the transducer. Do not exceed this limitation.
How to install the transducer HOW TO INSTALL THE TRANSDUCER Installation on a towed body Transducers designed to withstand large water pressure are provided for use in towed bodies. The recommended installation method is through the hull plating hull using mounting and clamping rings.
Simrad ES120-7CD Example 1: Small transducer The illustration below shows the installation principle of a small circular transducer using clamping and mounting rings. Figure 2 Installation principle, small transducer Mounting ring Hull plating on towed body Transducer Clamping ring Bolt...
How to install the transducer Example 2: Medium and large transducers The illustration below shows the installation principle of a medium or large transducers. Note that a clamping ring is not required, as the transducer body is shaped to facilitate this function.
Simrad ES120-7CD Example 3: Dual transducer arrangement The illustration below shows a typical through the hull installation of small and large circular transducers on a towed body. Figure 4 Dual transducer arrangement Small transducer Medium or larger transducer Electronic equipment in watertight compartment...
An anti-fouling paint may be applied to the transducer face. Because some paint types may be aggressive to the polyurethane in the transducer face, please consult Simrad’s list of approved paints. See Approved anti-fouling paints on page 14. Cleaning the transducer face...
Simrad ES120-7CD Approved anti-fouling paints This is Simrad’s list of approved antifouling paints on polyurethane transducer housing. Jotun Head office address: P.O.Box 2021, N-3248 Sandefjord, Norway Website: www.jotun.com. Racing Non-stop Safeguard Universal primer (125 micron) with Antifouling SeaQuantum Ultra (125 micron)
Transducer handling and maintenance Introduction to Emuge self-locking threads is a tap design with an integrated locking feature. Emuge self-lock Standard metric bolts are used. The internal thread provides a self-locking connection, which can be used repeatedly. It is not necessary to involve a secondary locking device (e.g.
Simrad ES120-7CD • Economically efficient locking system, no additional components are necessary • Undiminished holding power even under dynamic stress • Repeated loosening and re-tightening without loss of function • Internal threads can be produced with taps, cold Emuge forming taps or thread mills •...
Note that the gauge must be used Emuge self-lock in the correct direction. Self-lock taps provided by Simrad The following self-lock taps are on stock at Simrad, and can be ordered from us. Threads Drill diameter for Part.no threads ø5.2...
Simrad ES120-7CD DRAWING FILE This chapter contains relevant drawings related to the electrical and physical installation of the Simrad ES120-7CD Split-beam transducer. Note The mechanical drawings are for information and guidance only. They are not in scale, and may differ slightly from the original drawings.
Drawing file General Purpose Transceiver (GPT) wiring Observe the drawing below to connect the Simrad ES120-7CD Split-beam transducer to the General Purpose Transceiver (GPT). For more information about these connections, refer to the applicable echo sounder installation manual. 339149/A...