Designing, Manufacturing And Mounting The Steel Conduit - Simrad EC150-3C Installation Manual

Table of Contents

Advertisement

Installation
Further requirements
Before you can put the transducer cable through the cable gland, the steel conduit
must be installed.
Related topics
Installation summary, page 61
599-035130 Bushing EC150-3C, page 134
Designing, manufacturing and mounting the
steel conduit
A steel conduit is used to protect the transducer cable. The conduit serves two purposes.
It will protect the cable, and shield it from electric noise. Depending on how the steel
conduit is terminated over the transducer, it may also secure the watertight integrity
of the vessel.
Prerequisites
To design, manufacture and mount the steel conduit, the following prerequisites must be
met:
• All relevant vessel and transducer drawings must be available.
• All relevant work instructions, procedures and standards must be available.
• The physical location of the transducer has been determined.
• The installation method has been determined.
• The cable gland has been installed.
• All relevant personnel (naval architects, designers, skilled shipyard workers) and
tools must be available.
65