e.  Verify that the SCSI cable is securely connected to the RAID controller card.
f.  Replace the cover. See
g.  Stand the system upright.
h.  Install the bezel. See
11.  Format and partition the hard drive. See the operating system documentation.
12.  If possible, restore the files to the drive.
 
If the problem persists, see
 
Troubleshooting a Cabled SCSI Hard Drive
 
Problem
 Device driver error.
l
 Hard drive not recognized by the system.
l
 
Action
 
NOTICE:
This procedure can destroy data stored on the hard drive. Before you continue, back up all files on the hard drive.
1.  Run the appropriate online diagnostic test. See
 
If the test fails, continue to the next step.
2.  Run the SCSI controllers test and the hard drive tests in the system diagnostics. See
 
For information about testing the controller, see the SCSI or RAID controller card's documentation.
 
If the tests fail, continue to the next step.
3.  Restart the system and enter the configuration utility.
 
NOTE:
To enter the utility, press <Ctrl><h>, <Ctrl><a>, or <Ctrl><m>, depending on the utility. See the documentation supplied with the
controller for information about the configuration utility.
4.  Ensure that the primary SCSI channel is enabled, and restart the system. See the controller card's documentation.
5.  Ensure that the required device drivers are installed and configured correctly. See the Dell OpenManage Server Assistant CD.
 
CAUTION:
See your System Information Guide for complete information about safety precautions, working inside the computer, and protecting
against electrostatic discharge.
6.  Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
7.  Remove the bezel. See
"Removing the
8.  Lay the system on its right side.
9.  Remove the cover. See
"Removing the
10.  Ensure that the hard-drive interface cable is properly connected between the drive and the controller card. See the controller card's documentation.
11.  If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See
12.  Ensure that a power cable is properly connected to the drive.
13.  Ensure that the controller card is installed correctly.
14.  Ensure that the hard drive is configured with a unique SCSI ID number and that the drive is terminated or not terminated as appropriate. See the
documentation for the hard drive.
15.  Install the cover. See
"Replacing the
16.  Stand the system upright.
"Replacing the
Cover."
"Installing the
Bezel."
"Getting
Help."
"Using Server Administrator
Bezel."
Cover."
Cover."
Diagnostics" in "Running System Diagnostics."
"Running System
Diagnostics."
"Configuring the Boot
Drive" in "Installing Drives."