Dell PowerEdge 700 Installation And Troubleshooting Manual page 26

Systems
Hide thumbs Also See for PowerEdge 700:
Table of Contents

Advertisement

 
 Table 2-3. NIC Indicator Codes 
Indicator Normal Operation
 Activity
 Flashing amber indicates that network data is being sent or
received
 Link
 Steady green indicates that the network adapter is connected to a
valid link partner on the network.
 
Hot-Plug SCSI Hard-Drive Indicator Codes
 
Each SCSI hard-drive carrier has two indicators: a busy indicator and a status indicator (see Figure 2-4). The indicators provide information on the status of
the respective hard drive.
Figure 2-4. Hard-Drive Indicators
 
 
Table 2-4
lists the drive-status indicator codes. Different codes display as drive events occur in the system. For example, in the event of a hard-drive failure,
the "drive fail" code appears. After the drive is selected for removal, the "preparing for removal" code appears. After the replacement drive is installed, the
"preparing for operation, drive online" code appears.
 
The drive-busy indicator signifies whether the hard drive is active on the SCSI bus. This indicator is controlled by the hard drive.
 
 Table 2-4. SCSI Hard-Drive Status Indicator Codes 
Drive-Status Indicator
 Drive bay empty
 Drive being prepared for operation, drive online
 Drive being identified, prepared for removal, or drive offline  Blinks green 3 times per second at equal intervals
 Drive rebuilding
 Drive failed
 
Error Condition
 When off at the same time that the link indicator is off, the network
adapter is not connected to the network.
 When off at the same time that the activity indicator is off, the network
adapter is not connected to the network.
Indicator Code
 Off
 Steady green
 Blinks green once per second
 Steady amber

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents