SMC Networks HRS012-A-10 Series Service Manual page 157

Thermo-chiller
Hide thumbs Also See for HRS012-A-10 Series:
Table of Contents

Advertisement

5.
Remove the cable from the condenser.
6.
Remove the ground cable(G4) attached to the pump. (Screw ×1)
For the HRS030, cut the cable tie of the pump cable fixed to the fan motor bracket.
7.
Remove the hose attached to the pump. (2 pcs.)
8.
Remove the condenser. (Screw ×1)
9.
Remove the pump. (Screw ×4)
5
8
Removal of condenser
4
Removal
connector
[For HRS030]
Fan motor
bracket
7
Cable tie
 Mounting
1.
Mount the cap and bracket to the condenser,and it mount the electrical equipment panel.
(Screw ×1)
HRS Series
Removal of condenser cable
6
Ground cable
9
Removal pump
Fig. 4.5-6 Removal of high pressure pump
Condenser
Condenser bracket
Condenser cap
Fig. 4.5-7 Mount the condenser
Chapter 4
7
Removal
of hose
Screw
HRX-MM-N007
Service Procedure
3
Support panel
4.5 Replacement Procedure
4-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents