4.1 Consumable and gas flow selection

The tables in this chapter provide some basic guidance only and must not be considered as a definitive source of elec-
trode and gas flow rate information.
The welding current setting defines the electrode size and the shielding gas flow rate. The most typical shielding gas
for TIG welding is argon.
The following tables provide some basic guidance for the electrode size and shielding gas flow rate selection.
Welding current DC- (AC)
A
5...80 (5...50)
70...150 (30...100)
130...250 (80...150)
220...350 (120...210)
330...500 (180...280)
Electrode
Type
Symbol color
WC20
grey
WZ8
white
W
green
© Kemppi
Electrode
Gas nozzle
ø mm
Number
1.0
4/5
1.6
4/5/6
2.4
6/7
3.2
7/8/10
4.0
10/11/12
Welding current
Base material
Fe
Ss
AC, DC-
x
x
AC, DC-
AC, DC-
Gas flow rate
ø mm
l/min
6.5/8.0
5...6
6.5/8.0/9.5
6...7
9.5/11.0
7...8
11.0/12.5/16.0
8...10
16.0/17.5/19.0
10...12
Al
Ti
x